Accuracy of ultrasound measurements for skull bone thickness using coded signals.

Steffen H Tretbar1, Peter K Plinkert, Philipp A Federspil.   

Abstract

The knowledge of skull bone thickness would be helpful for a great variety of surgical interventions of the head. Ultrasound (US) can offer this information intraoperatively in real time. A-mode US measurements of skull bone thickness were performed with different pulse characteristics: 1) in water and 2) by directly coupling a 2.25-MHz US transducer integrated in a handpiece with a soft delay line using coded excitation (CE) (SonoPointer). Mechanical measurements by calipers served as controls. The specimen were 16 nonselected human cadaveric skull bones preserved with formaldehyde. The average difference between the bone thickness measured by the SonoPointer and the mechanical control measurements was 0.04 +/- 0.62 mm. The 95% limits of agreement between the two methods were -1.18 and 1.25 mm. However, even the gold standard of two repeated caliper measurements had limits of agreement of -0.4 and 0.42 mm. Using a standard US pulse in water, only 62.5% sample points were measurable, whereas the SonoPointer produced the thickness measurement in 97.9% of points. CE proved to be superior to single burst or needle US pulses. A-mode US measurements of skull bone thickness using the SonoPointer are feasible. It may provide valuable information on skull bone thickness, e.g., for osteosynthesis, calvarial split bone harvesting, implantation of hearing devices, osseointegrated titanium fixtures, and skull base surgery.

Entities:  

Mesh:

Year:  2009        PMID: 19174348     DOI: 10.1109/TBME.2008.2011058

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  3 in total

Review 1.  [Surgical technique in cochlear implantation].

Authors:  M Praetorius; H Staecker; P K Plinkert
Journal:  HNO       Date:  2009-07       Impact factor: 1.284

2.  Numerical Evaluation of the Influence of Skull Heterogeneity on Transcranial Ultrasonic Focusing.

Authors:  Chen Jiang; Dan Li; Feng Xu; Ying Li; Chengcheng Liu; Dean Ta
Journal:  Front Neurosci       Date:  2020-04-15       Impact factor: 4.677

3.  Establishing sheep as an experimental species to validate ultrasound-mediated blood-brain barrier opening for potential therapeutic interventions.

Authors:  Matthew Pelekanos; Gerhard Leinenga; Mostafa Odabaee; Maryam Odabaee; Siamak Saifzadeh; Roland Steck; Jürgen Götz
Journal:  Theranostics       Date:  2018-04-03       Impact factor: 11.556

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.