Literature DB >> 19173051

Characterization of a high-performance portable GC with a chemiresistor array detector.

Qiongyan Zhong1, William H Steinecker, Edward T Zellers.   

Abstract

The laboratory characterization of a novel, second-generation portable gas chromatograph (GC) prototype designed for trace-level determinations of complex mixtures of volatile organic compounds (VOC) is described. The instrument incorporates a small, multi-stage adsorbent preconcentrator/injector (PCI), two series-coupled separation columns with fast, independent temperature-programming capabilities and junction-point pressure/flow control, and a detector consisting of an array of microfabricated chemiresistor (CR) sensors coated with thiolate-monolayer-protected gold nanoparticle films. Response patterns from the CR array are used in conjunction with chromatographic retention times to identify eluting mixture components. Scrubbed ambient air is used as the carrier gas. Enhancements in design relative to a previously reported first-generation prototype instrument have led to significant reductions in limits of detection as well as improvements in resolution, reliability, flexibility, and convenience. Key features of the instrument are characterized, with an emphasis on the tradeoffs in sensor array performance associated with operation at different temperatures and flow rates. The separation of a preconcentrated mixture of 31 VOCs in < 7 minutes is demonstrated. Projected detection limits are in the ppt range for most compounds, assuming a 1 L sample volume.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19173051     DOI: 10.1039/b810944c

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  5 in total

1.  A wireless hybrid chemical sensor for detection of environmental volatile organic compounds.

Authors:  Cheng Chen; Francis Tsow; Katherine Driggs Campbell; Rodrigo Iglesias; Erica Forzani; N J Tao
Journal:  IEEE Sens J       Date:  2013-05       Impact factor: 3.301

Review 2.  Recent developments in instrumentation for capillary electrophoresis and microchip-capillary electrophoresis.

Authors:  Jessica L Felhofer; Lucas Blanes; Carlos D Garcia
Journal:  Electrophoresis       Date:  2010-08       Impact factor: 3.535

Review 3.  Miniaturized Bio-and Chemical-Sensors for Point-of-Care Monitoring of Chronic Kidney Diseases.

Authors:  Antonio Tricoli; Giovanni Neri
Journal:  Sensors (Basel)       Date:  2018-03-22       Impact factor: 3.576

4.  A Microfluidic-Based Fabry-Pérot Gas Sensor.

Authors:  Jin Tao; Qiankun Zhang; Yunfeng Xiao; Xiaoying Li; Pei Yao; Wei Pang; Hao Zhang; Xuexin Duan; Daihua Zhang; Jing Liu
Journal:  Micromachines (Basel)       Date:  2016-02-25       Impact factor: 2.891

5.  An Optimized Adsorbent Sampling Combined to Thermal Desorption GC-MS Method for Trimethylsilanol in Industrial Environments.

Authors:  Jae Hwan Lee; Chunrong Jia; Yong Doo Kim; Hong Hyun Kim; Tien Thang Pham; Young Seok Choi; Young Un Seo; Ike Woo Lee
Journal:  Int J Anal Chem       Date:  2012-08-23       Impact factor: 1.885

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.