Literature DB >> 19169444

Simulated fatigue resistance of composite resin versus porcelain CAD/CAM overlay restorations on endodontically treated molars.

Pascal Magne1, Alena Knezevic.   

Abstract

OBJECTIVE: To assess the influence of material selection (porcelain versus composite resin) for overlay-type restoration of endodontically treated molars and its effect on the in vitro fatigue resistance and failure mode. METHOD AND MATERIALS: A standardized tooth preparation was applied to 30 extracted molars, including root canal treatment, 3-mm coverage of all cusps, a mesial box 1.5 mm below the cementoenamel junction (CEJ), a distal box in enamel, a glass-ionomer base, and immediately sealed dentin. Using the Cerec machine (Sirona), all teeth were restored with an overlay of standardized thickness and occlusal anatomy. Fifteen restorations were milled in the ceramic Vita MKII block (Vident) and the other 15 using the composite resin Paradigm MZ100 block (3M ESPE). The intaglio surfaces of the ceramic restorations were etched and silanated. The intaglio surfaces of the composite resin overlays were airborne-particle abraded and silanated. Preparations were airborne-particle abraded and etched before restoration insertion. All restorations were adhesively luted with an adhesive resin (Optibond FL, Kerr) and a light-curing composite resin (Filtek Z100, 3M ESPE). Cyclic isometric chewing (5 Hz) was simulated, starting with a load of 200 N (5,000 cycles), followed by stages of 400, 600, 800, 1,000, 1,200, and 1,400 N at a maximum of 30,000 cycles each. Samples were loaded until fracture or to a maximum of 185,000 cycles.
RESULTS: MKII overlays fractured at a mean load of 1,147 N, and none of them withstood all 185,000 loading cycles (survival = 0%); with MZ100, the survival rate was 73%. With MKII, 40% of the fractures ended below the CEJ; with MZ100, only 25% did.
CONCLUSIONS: Composite resin MZ100 increased the fatigue resistance of overlay-type restorations in endodontically treated molars when compared to porcelain MKII. The efficiency of the bond strategy (immediate dentin sealing) was demonstrated by the absence of adhesive failures.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19169444

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  18 in total

1.  In vitro evaluation of marginal and internal adaptation of class II CAD/CAM ceramic restorations with different resinous bases and interface treatments.

Authors:  María José Sandoval; Giovanni Tommaso Rocca; Ivo Krejci; Michael Mandikos; Didier Dietschi
Journal:  Clin Oral Investig       Date:  2015-04-16       Impact factor: 3.573

2.  The influence of FRCs reinforcement on marginal adaptation of CAD/CAM composite resin endocrowns after simulated fatigue loading.

Authors:  Giovanni Tommaso Rocca; Carlo Massimo Saratti; Antoine Poncet; Albert J Feilzer; Ivo Krejci
Journal:  Odontology       Date:  2015-04-09       Impact factor: 2.634

Review 3.  Resin-composite blocks for dental CAD/CAM applications.

Authors:  N D Ruse; M J Sadoun
Journal:  J Dent Res       Date:  2014-10-24       Impact factor: 6.116

4.  [Decision-making of restorations for endodontically treated teeth].

Authors:  Chen Zhi; Chen Binwen
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2015-04

5.  Marginal adaptation of ceramic and composite inlays in minimally invasive mod cavities.

Authors:  M Zaruba; R Kasper; R Kazama; F J Wegehaupt; A Ender; T Attin; A Mehl
Journal:  Clin Oral Investig       Date:  2013-05-01       Impact factor: 3.573

6.  Polymer infiltrated ceramic network structures for resistance to fatigue fracture and wear.

Authors:  Haifa El Zhawi; Marina R Kaizer; Asima Chughtai; Rafael R Moraes; Yu Zhang
Journal:  Dent Mater       Date:  2016-08-29       Impact factor: 5.304

7.  The effect of different pretreatment methods of PMMA-based crowns on the long-term tensile bond strength to dentin abutments.

Authors:  Christine Keul; Daliah Kohen; Marlis Eichberger; Malgorzata Roos; Wolfgang Gernet; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2014-03-02       Impact factor: 3.573

8.  Tensile bond strength of resin composite repair in vitro using different surface preparation conditionings to an aged CAD/CAM resin nanoceramic.

Authors:  Bogna Stawarczyk; Andreas Krawczuk; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2014-06-15       Impact factor: 3.573

9.  In vitro assessment of single-retainer tooth-colored adhesively fixed partial dentures for posterior teeth.

Authors:  Tissiana Bortolotto; Carlo Monaco; Ioana Onisor; Ivo Krejci
Journal:  Int J Dent       Date:  2010-06-21

10.  Fatigue resistance of CAD/CAM resin composite molar crowns.

Authors:  Fatma A Shembish; Hui Tong; Marina Kaizer; Malvin N Janal; Van P Thompson; Niek J Opdam; Yu Zhang
Journal:  Dent Mater       Date:  2016-01-08       Impact factor: 5.304

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.