Literature DB >> 19167855

Evaluation of chemometric algorithms in quantitative X-ray powder diffraction (XRPD) of intact multi-component consolidated samples.

Michael D Moore1, Robert P Cogdill, Peter L D Wildfong.   

Abstract

Quantitative X-ray powder diffraction (XRPD) data obtained from intact, consolidated samples affords the opportunity to analyze mixtures that simulate pharmaceutical drug products without the need for reversion back to powders; an analytical preparation step that destroys the contextual solid-state information intrinsic to intact consolidated samples. Traditional, standardless quantitative methods generally involve sophisticated pattern refinement procedures (e.g., Rietveld refinement) and are limited to crystalline materials. Methods that incorporate an internal standard are not optimal for compact analysis, and may often be susceptible to prediction errors associated with intensity attenuation. Chemometric-based XRPD utilizes full-pattern methods that combine analyses of both Bragg diffraction and diffuse scatter, thereby allowing for enhancement of signal-to-noise, sensitivity, and selectivity. Classical least-squares (CLS) regression, principal components regression (PCR) and partial least squares (PLS) regression are three chemometric algorithms commonly employed in spectroscopy. In the present work, quantification of a consolidated four-component system, composed of two crystalline materials and two disordered materials was analyzed intact, using two different XRPD optics geometries. Calibrations constructed for the prediction of individual constituent concentrations using the aforementioned three multi-variate algorithms were statistically compared with traditional diffraction-absorption univariate calibration. PLS regression modeling of data collected in transmission geometry provided the best statistical results for the quantification of constituent concentration. Further, this calibration was minimally affected by diffraction pattern anomalies traditionally corrected prior to phase quantification.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19167855     DOI: 10.1016/j.jpba.2008.12.007

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  1 in total

1.  Quantification of Process Induced Disorder in Milled Samples Using Different Analytical Techniques.

Authors:  Ulrike Zimper; Jaakko Aaltonen; Cushla M McGoverin; Keith C Gordon; Karen Krauel-Goellner; Thomas Rades
Journal:  Pharmaceutics       Date:  2010-02-16       Impact factor: 6.321

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.