Literature DB >> 19167177

Management of acute malignant colorectal obstruction with a novel self-expanding metallic stent as a bridge to surgery.

Yong-Dong Li1, Ying-Sheng Cheng, Ming-Hua Li, You-Ben Fan, Ni-Wei Chen, Yu Wang, Jun-Gong Zhao.   

Abstract

PURPOSE: To prospectively evaluate the safety and clinical efficacy of a newly designed self-expandable metallic stent (SEMS) in the treatment of patients with acute malignant colorectal obstruction.
METHODS: Between April 2001 and October 2007, 52 patients with acute malignant colorectal obstruction were treated with a new designed SEMS as an investigational bridge to surgery. Patients were prospectively followed and relevant data collection was collected, including details regarding technique, clinical symptoms, complications, need for elective surgery, and overall survival.
RESULTS: Stent placement was technically successful in all but two patients (due to complete obstruction) with no procedure-related complications. Complications included stent migration (n=4), anal pain (n=2) and stool impaction (n=1). Clinical success was achieved in 49 (98%) of 50 patients with resolution of bowel obstruction within 2 days of stent placement. In one patient with stool impaction 2 days after stent placement, endoscopic disimpaction was successfully performed. An elective one-stage surgical procedure was performed in all 50 patients who successfully received a SEMS as a bridge to surgery within a mean of 8+/-2 days (range: 4-11 days) after stent placement. Mean follow-up time was 36+/-12 months (range 3-70 months), and all patients remained alive at the time of this report.
CONCLUSION: The newly designed SEMS placement as a bridge to surgery was a safe and effective intervention for colonic decompression in patients with acute malignant colorectal obstruction and allowed a high proportion of patients to be successfully proceeded to elective surgery. Copyright 2008 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19167177     DOI: 10.1016/j.ejrad.2008.12.004

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  10 in total

1.  Duodenal and colonic stent placement with 0.025″ and 0.035″ guidewires is equally safe and effective.

Authors:  Jessica Chan; Kristen Hilden; John Fang; Douglas G Adler
Journal:  Dig Dis Sci       Date:  2011-10-08       Impact factor: 3.199

Review 2.  Self-Expanding Metallic Stents for the Management of Emergency Malignant Large Bowel Obstruction: a Systematic Review.

Authors:  Yasoba Nayanapriya Atukorale; Jody Lynne Church; Benjamin Lee Hoggan; Robyn Sheree Lambert; Stefanie Lynette Gurgacz; Stephen Goodall; Guy J Maddern
Journal:  J Gastrointest Surg       Date:  2016-02       Impact factor: 3.452

3.  A temporary self-expanding metallic stent for malignant colorectal obstruction.

Authors:  Xiao-Li Ding; Yong-Dong Li; Rui-Min Yang; Fen-Bao Li; Ming-Qiu Zhang
Journal:  World J Gastroenterol       Date:  2013-02-21       Impact factor: 5.742

4.  Comparison of self-expanding metal stents and urgent surgery for left-sided malignant colonic obstruction in elderly patients.

Authors:  Ming-Gao Guo; Yi Feng; Qi Zheng; Jian-Zhong Di; Yu Wang; You-Ben Fan; Xin-Yu Huang
Journal:  Dig Dis Sci       Date:  2011-03-27       Impact factor: 3.199

5.  Predictors of outcome for endoscopic colorectal stenting: a decade experience.

Authors:  Maher A Abbas; Greg Kharabadze; Ethan M Ross; Mohammad A Abbass
Journal:  Int J Colorectal Dis       Date:  2016-11-05       Impact factor: 2.571

6.  Does stenting of left-sided colorectal cancer as a "bridge to surgery" adversely affect oncological outcomes? A comparison with non-obstructing elective left-sided colonic resections.

Authors:  Alexandra L Knight; Vasileios Trompetas; Mike P Saunders; Hugh J Anderson
Journal:  Int J Colorectal Dis       Date:  2012-06-09       Impact factor: 2.571

Review 7.  Definition of large bowel obstruction by primary colorectal cancer: A systematic review.

Authors:  Joyce V Veld; Kim J Beek; Esther C J Consten; Frank Ter Borg; Henderik L van Westreenen; Wilhelmus A Bemelman; Jeanin E van Hooft; Pieter J Tanis
Journal:  Colorectal Dis       Date:  2021-01-15       Impact factor: 3.788

8.  Evidence-based recommendations on colorectal stenting: a report from the stent study group of the korean society of gastrointestinal endoscopy.

Authors:  Kwang Jae Lee; Sang Woo Kim; Tae Il Kim; Jong-Hoon Lee; Bo-In Lee; Bora Keum; Dae Young Cheung; Chang Heon Yang
Journal:  Clin Endosc       Date:  2013-07-31

9.  Own experiences of endoscopic self-expandable stent placement for malignant colorectal ileus.

Authors:  Zbigniew K Kamocki; Konrad P Zaręba; Roman Bandurski; Andrzej Baniukiewicz; Eugeniusz Wróblewski; Mariusz Gryko; Bogusław Kędra
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2014-01-30       Impact factor: 1.195

10.  Comparison of One-Stage Managements in the Treatment of Obstructing Left-Sided Colorectal Cancer: Endolaparoscopic Approach vs. Emergency Open Surgery.

Authors:  Yingdong Cheng; Hua Yang; Zhicao Zhang; Guoqing Chen; Guangsheng DU; Dan Ma
Journal:  Iran J Public Health       Date:  2015-08       Impact factor: 1.429

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.