Literature DB >> 19166768

Consistency of apex locator function: a clinical study.

Ashraf ElAyouti1, Eleftheria Dima, Julia Ohmer, Kristina Sperl, Christiane von Ohle, Claus Löst.   

Abstract

The consistency of apex locators was determined by calculating the dysfunction frequency. Electronic working length (EWL) was determined in 507 patients requiring endodontic treatment. Different clinical parameters were recorded including tooth vitality, presence of obliteration, and metallic restoration. Two apex locators were used (Root ZX [Morita, Tokyo, Japan] and Raypex5 [VDW, Munich, Germany]). Apex locator performance was considered "consistent" when the scale bars were stable and moved only in correspondence to the movement of file in the root canal. A working length radiograph with files set to the EWL was performed. EWL were considered "acceptable" when the file tip was located 0 to 2 mm short of the radiographic apex. The function of apex locators was consistent in 85% of the patients (429/507 [99% confidence interval, 80-88]). The inconsistent measurements were strongly associated with partially or totally obliterated root canals (p < 0.0001). Radiographically, 97% of consistent measurements were "acceptable."

Entities:  

Mesh:

Year:  2008        PMID: 19166768     DOI: 10.1016/j.joen.2008.10.017

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  5 in total

1.  Clinical evaluation of Root ZX II electronic apex locator in primary teeth.

Authors:  S Saritha; K S Uloopi; C Vinay; R Chandra Sekhar; V V Rao
Journal:  Eur Arch Paediatr Dent       Date:  2012-02

2.  A comparative clinical evaluation of accuracy of six apex locators with intraoral periapical radiograph in multirooted teeth: An in vivo study.

Authors:  Prahlad A Saraf; P Ratnakar; Thimmanagowda N Patil; Raghavendra Penukonda; Laxmikant Kamatagi; Sneha S Vanaki
Journal:  J Conserv Dent       Date:  2017 Jul-Aug

3.  Comparison of Tentative Radiographic Working Length with and without grid Versus Electronic Apex Locator.

Authors:  Tanikonda Rambabu; Visinigiri Srikanth; Girija S Sajjan; Sirisha Ganguru; Chava Gayatri; K Roja
Journal:  Contemp Clin Dent       Date:  2018 Jan-Mar

4.  Effect of Orthodontic Brackets on the Accuracy of Apex Locators: A Pilot Study.

Authors:  Özgür Genç Şen; Özgür İlke Ulusoy; Yelda Nayır Paltun; Çağrı Ulusoy
Journal:  Biomed Res Int       Date:  2021-04-24       Impact factor: 3.411

5.  Reliability and accuracy of dental MRI for measuring root canal length of incisors and canines: a clinical pilot study.

Authors:  Mousa Zidan; Franz S Schwindling; Alexander Juerchott; Johannes Mente; Mathias Nittka; Zahra Hosseini; Sabine Heiland; Martin Bendszus; Tim Hilgenfeld
Journal:  Sci Rep       Date:  2022-08-18       Impact factor: 4.996

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.