Multimodality image guided total marrow irradiation and verification of the dose delivered to the lung, PTV, and thoracic bone in a patient: a case study.

Susanta K Hui1, M R Verneris, Jerry Froelich, K Dusenbery, James S Welsh.   

Abstract

This work reports our initial experience using multimodality image guidance to improve total marrow irradiation (TMI) using helical tomotherapy. We also monitored the details of the treatment delivery to glean information necessary for the implementation of future adaptive processes. A patient with metastatic Ewing's sarcoma underwent MRI, and bone scan imaging prior to TMI. A whole body kilovoltage CT (kVCT) scan was obtained for intensity modulated TMI treatment planning, including a boost treatment to areas of bony involvement. The delivered dose was estimated by using MVCT images from the helical tomotherapy treatment unit, compared to the expected dose distributions mapped onto the kVCT images. Clinical concerns regarding patient treatment and dosimetric uncertainties were also evaluated. A small fraction of thoracic bone volume received lower radiation dose than the prescribed dose. Reconstructed planned treatment volume (PTV) and the dose delivered to the lung were identical to planned dose. Bone scan imaging had a higher sensitivity for detecting skeletal metastasis compared to MR imaging. However the bone scan lacked sufficient specificity in three dimensions to be useful for planning conformal radiation boost treatments. Inclusion of appropriate imaging modalities improves detection of metastases, which allows the possibility of a radiation dose boost to metastases during TMI. Conformal intensity modulated radiation therapy via helical tomotherapy permitted radiation delivery to metastases in the skull with reduced dose to brain in conjunction with TMI. While TMI reduces irradiation to the lungs, onboard megavoltage computed tomography (MVCT) to verify accurate volumetric dose coverage to marrow-containing thoracic bones may be essential for successful conformal TMI treatment.

Entities:  

Mesh:

Year:  2009        PMID: 19166239     DOI: 10.1177/153303460900800104

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  11 in total

1.  Feasibility of intrafraction whole-body motion tracking for total marrow irradiation.

Authors:  Manju Sharma; Troy Dos Santos; Nikolaos P Papanikolopoulos; Susanta Kumar Hui
Journal:  J Biomed Opt       Date:  2011-05       Impact factor: 3.170

2.  Peripheral dose heterogeneity due to the thread effect in total marrow irradiation with helical tomotherapy.

Authors:  Yutaka Takahashi; Michael R Verneris; Kathryn E Dusenbery; Christopher T Wilke; Guy Storme; Daniel J Weisdorf; Susanta K Hui
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-09-05       Impact factor: 7.038

3.  Three-dimensional patient setup errors at different treatment sites measured by the Tomotherapy megavoltage CT.

Authors:  S K Hui; E Lusczek; T DeFor; K Dusenbery; S Levitt
Journal:  Strahlenther Onkol       Date:  2012-03-09       Impact factor: 3.621

4.  Multi-institutional feasibility study of a fast patient localization method in total marrow irradiation with helical tomotherapy: a global health initiative by the international consortium of total marrow irradiation.

Authors:  Yutaka Takahashi; Stefano Vagge; Stefano Agostinelli; Eunyoung Han; Lukasz Matulewicz; Kai Schubert; Ravishankar Chityala; Vaneerat Ratanatharathorn; Koen Tournel; Jose A Penagaricano; Sterzing Florian; Marc-Andre Mahe; Michael R Verneris; Daniel J Weisdorf; Renzo Corvo; Kathryn E Dusenbery; Guy Storme; Susanta K Hui
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-10-30       Impact factor: 7.038

5.  Dose Escalation of Total Marrow Irradiation in High-Risk Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation.

Authors:  Susanta Hui; Claudio Brunstein; Yutaka Takahashi; Todd DeFor; Shernan G Holtan; Veronika Bachanova; Christopher Wilke; Darren Zuro; Celalettin Ustun; Daniel Weisdorf; Kathryn Dusenbery; Michael R Verneris
Journal:  Biol Blood Marrow Transplant       Date:  2017-04-07       Impact factor: 5.742

6.  Radiation response of mesenchymal stem cells derived from bone marrow and human pluripotent stem cells.

Authors:  Mohammad S Islam; Melissa E Stemig; Yutaka Takahashi; Susanta K Hui
Journal:  J Radiat Res       Date:  2014-11-24       Impact factor: 2.724

Review 7.  Total marrow irradiation for hematopoietic malignancies using volumetric modulated arc therapy: A review of treatment planning studies.

Authors:  Pietro Mancosu; Luca Cozzi; Ludvig Paul Muren
Journal:  Phys Imaging Radiat Oncol       Date:  2019-08-29

8.  Optimized Conformal Total Body Irradiation methods with Helical TomoTherapy and Elekta VMAT: Implementation, Imaging, Planning and Dose Delivery for Pediatric Patients.

Authors:  Anna Anzorovna Loginova; Diana Anatolievna Tovmasian; Anastasiya Olegovna Lisovskaya; Daria Alexeevna Kobyzeva; Michael Alexandrovich Maschan; Alexander Petrovich Chernyaev; Oleg Borisovich Egorov; Alexey Vladimirovich Nechesnyuk
Journal:  Front Oncol       Date:  2022-03-10       Impact factor: 6.244

9.  Impact of very long time output variation in the treatment of total marrow irradiation with helical tomotherapy.

Authors:  Yutaka Takahashi; Susanta K Hui
Journal:  Radiat Oncol       Date:  2013-05-20       Impact factor: 3.481

10.  Fast, simple, and informative patient-specific dose verification method for intensity modulated total marrow irradiation with helical tomotherapy.

Authors:  Yutaka Takahashi; Susanta K Hui
Journal:  Radiat Oncol       Date:  2014-01-25       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.