Digital titration: automated image acquisition and analysis of load and growth of Chlamydophila psittaci.

Delphine S A Beeckman1, Geert Meesen, Patrick Van Oostveldt, Daisy Vanrompay.   

Abstract

Traditionally, the amount of infective chlamydiae in a given sample is determined by inoculating dilution series into cell cultures and physically counting chlamydial inclusions. This approach is time consuming, tedious, and error prone, mainly when dealing with high titers. Therefore, this paper describes a largely automated technique that was developed to standardize the determination of chlamydial load in vitro. Cells are fixed at 36 h post-inoculation and bacteria visualized using standard immunological detection methods. Consequently, for 81 microscopic fields, an image is recorded at the interpolated focal plane. These images are then automatically processed using an ImageJ plugin and the obtained results are imported into Excel to determine the number of inclusion forming units per mL in the sample. The main advantage of this technique is that no or minimal sample dilution is required, thus minimizing dilution errors. In addition, this technique was employed during the early, middle and late growth stages of the chlamydial developmental cycle and results correlated well (P < 0.01) with 16S rRNA values from previous experiments, thereby proving its suitability to follow chlamydial growth in vitro. The method described is highly suitable for high throughput titration of cell culture inoculated samples and assessment of possible antichlamydial effects of novel compounds throughout the chlamydial growth cycle. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19165738     DOI: 10.1002/jemt.20694

Source DB:  PubMed          Journal:  Microsc Res Tech        ISSN: 1059-910X            Impact factor:   2.769


  4 in total

1.  Application of DNA chip scanning technology for automatic detection of Chlamydia trachomatis and Chlamydia pneumoniae inclusions.

Authors:  Anita Bogdanov; Valeria Endrész; Szabolcs Urbán; Ildikó Lantos; Judit Deák; Katalin Burián; Kamil Önder; Ferhan Ayaydin; Péter Balázs; Dezso P Virok
Journal:  Antimicrob Agents Chemother       Date:  2013-11-04       Impact factor: 5.191

2.  Simple resazurin-based microplate assay for measuring Chlamydia infections.

Authors:  Ichie Osaka; P Scott Hefty
Journal:  Antimicrob Agents Chemother       Date:  2013-03-18       Impact factor: 5.191

3.  Application of ImageJ program to the enumeration of Orientia tsutsugamushi organisms cultured in vitro.

Authors:  Sontana Siritantikorn; Suthatip Jintaworn; Sansanee Noisakran; Yupin Suputtamongkol; Daniel H Paris; Stuart D Blacksell
Journal:  Trans R Soc Trop Med Hyg       Date:  2012-07-11       Impact factor: 2.184

4.  The immune response against Chlamydia suis genital tract infection partially protects against re-infection.

Authors:  Evelien De Clercq; Bert Devriendt; Lizi Yin; Koen Chiers; Eric Cox; Daisy Vanrompay
Journal:  Vet Res       Date:  2014-09-25       Impact factor: 3.683