Literature DB >> 19164411

Immediate loading of orthodontic mini-implants: a histomorphometric evaluation of tissue reaction.

Cesare Luzi1, Carlalberta Verna, Birte Melsen.   

Abstract

Although immediate loading of orthodontic mini-implants can be clinically successful, a lack of histological data exists. The present investigation was performed to evaluate, in an animal model, tissue reaction to immediate loading. Fifty orthodontic titanium mini-implants were inserted in four adult male monkeys at four time intervals. Forty-two devices were loaded with 50 cN super-elastic coil springs immediately after insertion while eight were left unloaded and served as the controls. After euthanasia, the following histomorphometric parameters were evaluated: bone volume (BV/TV), bone-to-implant contact (BIC), mineralizing surface (MS/BS), and erosion surface (ES/BS). Statistical analysis was performed by means of non-parametric tests. Four devices were removed because of loss of stability. A wide variation between animals was found for all parameters. BV/TV: slightly higher values were found in the unloaded sample. Although no particular trend was observed, at 3 months higher values were found in the lower jaw. BIC: a trend to a decrease between 1 week and 1 month followed by a significantly progressive increase was observed. Implants that showed some sections with as little as 3 per cent BIC successfully resisted loading. MS/BS: higher values were found in the lower jaw. MS/BS increased significantly between 1 week and 1 month, followed by a progressive decrease. ES/BS: there was a decrease between 1 week and 1 month, followed by a progressive re-increase. BV/TV did not show any particular trend while BIC was a time-dependent factor. MS/BS and ES/BS demonstrated opposite trends during the healing period. Immediate loading with light forces did not negatively affect the bone healing pattern.

Entities:  

Mesh:

Year:  2009        PMID: 19164411     DOI: 10.1093/ejo/cjn087

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  6 in total

1.  Orthodontics at a Pivotal Point of Transformation.

Authors:  Jeremy J Mao
Journal:  Semin Orthod       Date:  2010-06-01       Impact factor: 0.970

2.  In vivo evaluation of immediately loaded stainless steel and titanium orthodontic screws in a growing bone.

Authors:  Kerstin Gritsch; Norbert Laroche; Jeanne-Marie Bonnet; Patrick Exbrayat; Laurent Morgon; Muriel Rabilloud; Brigitte Grosgogeat
Journal:  PLoS One       Date:  2013-10-04       Impact factor: 3.240

3.  Implant Survival between Endo-osseous Dental Implants in Immediate Loading, Delayed Loading, and Basal Immediate Loading Dental Implants a 3-Year Follow-up.

Authors:  Ritesh Garg; Neha Mishra; Mohan Alexander; Sunil Kumar Gupta
Journal:  Ann Maxillofac Surg       Date:  2017 Jul-Dec

4.  Periodontopathogens around the surface of mini-implants removed from orthodontic patients.

Authors:  André Tortamano; Gladys Cristina Dominguez; Ana Cristina Soares Santos Haddad; Fabio Daumas Nunes; Mônica Nacao; Camillo Morea
Journal:  Angle Orthod       Date:  2012-07       Impact factor: 2.079

5.  Effects of immediate orthodontic and orthopedic forces on peri-miniscrew bones: histomorphologic and histomorphometric assessment in dogs.

Authors:  Mansour Rismanchian; Sayed Hamid Raji; Danesh Teimori Rik; Sayed Mohammad Razavi; Navid Khalighinejad; Hossein Goroohi; Hamid Badrian
Journal:  Int J Dent       Date:  2012-12-25

6.  Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.

Authors:  Barat Ali Ramazanzadeh; Kazem Fatemi; Mahboobe Dehghani; Nooshin Mohtasham; Arezoo Jahanbin; Hamed Sadeghian
Journal:  ISRN Dent       Date:  2014-04-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.