Literature DB >> 19163665

Design of a continuous passive and active motion device for hand rehabilitation.

B Birch1, E Haslam, I Heerah, N Dechev, E J Park.   

Abstract

This paper presents the design of a novel, portable device for hand rehabilitation. The device provides for CPM (continuous passive motion) and CAM (continuous active motion) hand rehabilitation for patients recovering from damage such as flexor tendon repair and strokes. The device is capable of flexing/extending the MCP (metacarpophalangeal) and PIP (proximal interphalangeal) joints through a range of motion of 0 degrees to 90 degrees for both the joints independently. In this way, typical hand rehabilitation motions such as intrinsic plus, intrinsic minus, and a fist can be achieved without the need of any splints or attachments. The CPM mode is broken into two subgroups. The first mode is the use of preset waypoints for the device to cycle through. The second mode involves motion from a starting position to a final position, but senses the torque from the user during the cycle. Therefore the user can control the ROM by resisting when they are at the end of the desired motion. During the CPM modes the device utilizes a minimum jerk trajectory model under PD control, moving smoothly and accurately between preselected positions. CAM is the final mode where the device will actively resist the movement of the user. The user moves from a start to end position while the device produces a torque to resist the motion. This active resistance motion is a unique ability designed to mimic the benefits of a human therapist. Another unique feature of the device is its ability to independently act on both the MCP and PIP joints. The feedback sensing built into the device makes it capable of offering a wide and flexible range of rehabilitation programs for the hand.

Entities:  

Mesh:

Year:  2008        PMID: 19163665     DOI: 10.1109/IEMBS.2008.4650162

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

1.  The response of the autonomic nervous system to passive lower limb movement and gender differences.

Authors:  Ping Shi; Sijung Hu; Hongliu Yu
Journal:  Med Biol Eng Comput       Date:  2015-08-29       Impact factor: 2.602

2.  Development of an Exoskeleton Platform of the Finger for Objective Patient Monitoring in Rehabilitation.

Authors:  Nikolas Jakob Wilhelm; Sami Haddadin; Jan Josef Lang; Carina Micheler; Florian Hinterwimmer; Anselm Reiners; Rainer Burgkart; Claudio Glowalla
Journal:  Sensors (Basel)       Date:  2022-06-25       Impact factor: 3.847

Review 3.  A structured overview of trends and technologies used in dynamic hand orthoses.

Authors:  Ronald A Bos; Claudia J W Haarman; Teun Stortelder; Kostas Nizamis; Just L Herder; Arno H A Stienen; Dick H Plettenburg
Journal:  J Neuroeng Rehabil       Date:  2016-06-29       Impact factor: 4.262

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.