Literature DB >> 19163004

Continuous cuff-less blood pressure monitoring based on the pulse arrival time approach: the impact of posture.

J Muehlsteff1, X A Aubert, G Morren.   

Abstract

There is an unmet need for cuff-less blood pressure (BP) monitoring especially, in personal healthcare applications. The pulse arrival time (PAT) approach might offer a suitable solution to enable comfortable BP monitoring even at beat-level. However, the methodology is based on hemodynamic surrogate measures, which are sensitive to patient activities such as posture changes, not necessarily related to blood pressure variations. In this paper, we analyze the impact of posture on the PAT measure and related hemodynamic parameters such as the pre-ejection period in well-defined procedures. Additionally, the PAT of a monitored subject is investigated in an unsupervised scenario illustrating the complexity of such a measurement. Our results show the failure of blood pressure inference based on simple calibration strategies using the PAT measure only. We discuss opportunities to compensate for the observed effects towards the realization of wearable cuff-less blood pressure monitoring. These findings emphasize the importance of accessing context information in personal healthcare applications, where vital sign monitoring is typically unsupervised.

Entities:  

Mesh:

Year:  2008        PMID: 19163004     DOI: 10.1109/IEMBS.2008.4649501

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  6 in total

1.  Implementation of compressed sensing in telecardiology sensor networks.

Authors:  Eduardo Correia Pinheiro; Octavian Adrian Postolache; Pedro Silva Girão
Journal:  Int J Telemed Appl       Date:  2010-09-21

Review 2.  Wearable sensors in syncope management.

Authors:  Christian Meyer; Paulo Carvalho; Christoph Brinkmeyer; Malte Kelm; Ricardo Couceiro; Jens Mühlsteff
Journal:  Med Sci Monit       Date:  2015-01-22

3.  Blood Pressure Estimation Using On-body Continuous Wave Radar and Photoplethysmogram in Various Posture and Exercise Conditions.

Authors:  Malikeh Pour Ebrahim; Fatemeh Heydari; Taiyang Wu; Katherine Walker; Keith Joe; Jean-Michel Redoute; Mehmet Rasit Yuce
Journal:  Sci Rep       Date:  2019-11-08       Impact factor: 4.379

4.  A Novel Physical Fatigue Assessment Method Utilizing Heart Rate Variability and Pulse Arrival Time towards Personalized Feedback with Wearable Sensors.

Authors:  Ardo Allik; Kristjan Pilt; Moonika Viigimäe; Ivo Fridolin; Gert Jervan
Journal:  Sensors (Basel)       Date:  2022-02-21       Impact factor: 3.576

5.  Pulse arrival time as a surrogate of blood pressure.

Authors:  Eoin Finnegan; Shaun Davidson; Mirae Harford; João Jorge; Peter Watkinson; Duncan Young; Lionel Tarassenko; Mauricio Villarroel
Journal:  Sci Rep       Date:  2021-11-23       Impact factor: 4.379

6.  A wearable chemical-electrophysiological hybrid biosensing system for real-time health and fitness monitoring.

Authors:  Somayeh Imani; Amay J Bandodkar; A M Vinu Mohan; Rajan Kumar; Shengfei Yu; Joseph Wang; Patrick P Mercier
Journal:  Nat Commun       Date:  2016-05-23       Impact factor: 14.919

  6 in total