Literature DB >> 19162934

Variations in non-invasive radial artery pulse waveform at different measuring positions.

Jeon Lee1, Young-Ju Jeon, Hae-Jung Lee, Jong-Yeol Kim.   

Abstract

Noninvasive radial artery pulse wave has been widely not only for the pulse wave analysis (PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. In this study, we tested the differences between the extracted parameters, including AIx, from radial artery pulse waves measured at three different positions preliminarily. A 30 years old female involved in this experiment and this subject has no evidence about cardiovascular diseases. Radial pulse waves were recorded at three different positions on left lower arm ten times for each position. These positions are widely used in pulse diagnosis of traditional medicine.As results of repeated measures ANOVA analysis, 9 parameters were found which had significantly differences in between measuring positions (P<0.05). These parameters wereP_AIx, PP_Amp, A_T1, A_Tr, AIx, AIx_@HR75, ESP, MP_Sysand MP_Dia. And, by Spearman correlation test at P2, it was observed that P_AIx (r =0.894), PP_Amp (r=-0.765),AIx_@HR75 (r=0.929), ESP (r=0.893) and MP_Dia (r=0.792)were highly correlated with AIx. Elaborately, the correlation coefficients between each parameter were high in similar degrees (r>0.70).Further studies on what make differences in these parameters between measuring positions are need. And, ultimately, we need to determine the best measuring process, including measuring position, hold-down pressure, signal quality validation and so on,so to achieve the optimal waveform which represents subject's health condition for both western medicine and traditional medicine.

Entities:  

Mesh:

Year:  2008        PMID: 19162934     DOI: 10.1109/IEMBS.2008.4649431

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  2 in total

1.  Novel diagnostic algorithm for the floating and sunken pulse qualities and its clinical test.

Authors:  Jaeuk U Kim; Young Ju Jeon; Yu Jung Lee; Keun Ho Kim; Jong Yeol Kim
Journal:  Evid Based Complement Alternat Med       Date:  2011-03-01       Impact factor: 2.629

2.  A clinical study of the pulse wave characteristics at the three pulse diagnosis positions of chon, gwan and cheok.

Authors:  Young J Jeon; Jaeuk U Kim; Hae J Lee; Jeon Lee; Hyun H Ryu; Yu J Lee; Jong Y Kim
Journal:  Evid Based Complement Alternat Med       Date:  2011-05-02       Impact factor: 2.629

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.