Literature DB >> 19161200

Assessment of anterior cruciate ligament reconstruction using 3D ultrashort echo-time MR imaging.

Jürgen Rahmer1, Peter Börnert, Sebastian P M Dries.   

Abstract

This work demonstrates the potential of ultrashort TE (UTE) imaging for visualizing graft material and fixation elements after surgical repair of soft tissue trauma such as ligament or meniscal injury. Three asymptomatic patients with anterior cruciate ligament (ACL) reconstruction using different graft fixation methods were imaged at 1.5T using a 3D UTE sequence. Conventional multislice turbo spin-echo (TSE) measurements were performed for comparison. 3D UTE imaging yields high signal from tendon graft material at isotropic spatial resolution, thus facilitating direct positive contrast graft visualization. Furthermore, metal and biopolymer graft fixation elements are clearly depicted due to the high contrast between the signal-void implants and the graft material. Thus, the ability of UTE MRI to visualize short-T(2) tissues such as tendons, ligaments, or tendon grafts can provide additional information about the status of the graft and its fixation in the situation after cruciate ligament repair. UTE MRI can therefore potentially support diagnosis when problems occur or persist after surgical procedures involving short-T(2) tissues and implants.

Entities:  

Mesh:

Year:  2009        PMID: 19161200     DOI: 10.1002/jmri.21653

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  10 in total

1.  Review. The Agfa Mayneord lecture: MRI of short and ultrashort T₂ and T₂* components of tissues, fluids and materials using clinical systems.

Authors:  G M Bydder
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  T₁-weighted ultrashort echo time method for positive contrast imaging of magnetic nanoparticles and cancer cells bound with the targeted nanoparticles.

Authors:  Longjiang Zhang; Xiaodong Zhong; Liya Wang; Hongwei Chen; Y Andrew Wang; Julie Yeh; Lily Yang; Hui Mao
Journal:  J Magn Reson Imaging       Date:  2011-01       Impact factor: 4.813

3.  The effect of freeze-thawing on magnetic resonance imaging T2* of freshly harvested bovine patellar tendon.

Authors:  Sarah L Pownder; Parina H Shah; Hollis G Potter; Matthew F Koff
Journal:  Quant Imaging Med Surg       Date:  2015-06

Review 4.  Metal-induced artifacts in MRI.

Authors:  Brian A Hargreaves; Pauline W Worters; Kim Butts Pauly; John M Pauly; Kevin M Koch; Garry E Gold
Journal:  AJR Am J Roentgenol       Date:  2011-09       Impact factor: 3.959

Review 5.  Application of advanced magnetic resonance imaging techniques in evaluation of the lower extremity.

Authors:  Hillary J Braun; Jason L Dragoo; Brian A Hargreaves; Marc E Levenston; Garry E Gold
Journal:  Radiol Clin North Am       Date:  2013-03-09       Impact factor: 2.303

6.  Ultrashort echo time and zero echo time MRI at 7T.

Authors:  Peder E Z Larson; Misung Han; Roland Krug; Angela Jakary; Sarah J Nelson; Daniel B Vigneron; Roland G Henry; Graeme McKinnon; Douglas A C Kelley
Journal:  MAGMA       Date:  2015-12-24       Impact factor: 2.310

7.  Cardiac-respiratory self-gated cine ultra-short echo time (UTE) cardiovascular magnetic resonance for assessment of functional cardiac parameters at high magnetic fields.

Authors:  Verena Hoerr; Nina Nagelmann; Arno Nauerth; Michael T Kuhlmann; Jörg Stypmann; Cornelius Faber
Journal:  J Cardiovasc Magn Reson       Date:  2013-07-04       Impact factor: 5.364

8.  One in 5 Athletes Sustain Reinjury Upon Return to High-Risk Sports After ACL Reconstruction: A Systematic Review in 1239 Athletes Younger Than 20 Years.

Authors:  Sue Barber-Westin; Frank R Noyes
Journal:  Sports Health       Date:  2020-05-06       Impact factor: 3.843

Review 9.  Application of nanoparticles on diagnosis and therapy in gliomas.

Authors:  Norma Y Hernández-Pedro; Edgar Rangel-López; Roxana Magaña-Maldonado; Verónica Pérez de la Cruz; Abel Santamaría del Angel; Benjamín Pineda; Julio Sotelo
Journal:  Biomed Res Int       Date:  2013-04-18       Impact factor: 3.411

10.  Three Dimensional Ultra-short Echo Time MRI Can Depict Cholesterol Components of Gallstones Bright.

Authors:  Mamoru Takahashi; Yasuo Takehara; Kenji Fujisaki; Tomoyuki Okuaki; Yukiko Fukuma; Norihiro Tooyama; Katsutoshi Ichijo; Tomoyasu Amano; Satoshi Goshima; Shinji Naganawa
Journal:  Magn Reson Med Sci       Date:  2020-12-28       Impact factor: 2.471

  10 in total