Literature DB >> 19159850

Metal allergic reaction in chronic refractory in-stent restenosis.

Taro Saito1, Seiji Hokimoto, Syuichi Oshima, Katsuo Noda, Yasuko Kojyo, Kayoko Matsunaga.   

Abstract

OBJECTIVES: This study examined the relationship between chronic refractory (CR) in-stent restenosis (ISR) and metal allergic reaction.
BACKGROUND: Although drug-eluting stent reduced the restenotic event compared with bare-metal stent, the mechanism of neointimal proliferation is not clear yet; however, bare-metal stent still remains as one of the choices.
METHODS: Of 128 bare-metal stent implanted patients who experienced target lesion revascularization at least once, 60 patients with the second ISR (study group) and 68 patients without the second ISR (control group) were compared in terms of result from the skin patch test for metal allergic reaction.
RESULTS: Nickel was dominant among components of 316L stainless steel. The nickel-positive was observed in 19% (24/128) of all patients. Of 24 nickel-positive, 18 (30%) was in the study group, whereas 6 (9%) was in the control group (P=.02). According to multivariate analysis, the most significant predictor for CR-ISR was reference vessel diameter (P=.0010) followed by nickel-positive (P=.0033) and hyperlipidemia (P=.0305). The nickel-positive showed the highest odds ratio of 5.41 adjusted with confounder variables.
CONCLUSION: This study with the second ISR showed that nickel was a major factor for CR-ISR. Further improvement of biocompatible material is required for coronary stents and strut-coating materials even in the drug-eluting stent era.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19159850     DOI: 10.1016/j.carrev.2008.01.004

Source DB:  PubMed          Journal:  Cardiovasc Revasc Med        ISSN: 1878-0938


  10 in total

1.  Long-term angiographic outcomes of post-sirolimus-eluting stent restenosis in Japanese patients.

Authors:  Nobuyuki Miyai; Noriyuki Kinoshita; Keisuke Oota; Takeshi Yamada; Reo Nakamura; Hidekazu Irie; Tetsuo Hashimoto; Shyunichi Tamaki; Hiroaki Matsubara
Journal:  Heart Vessels       Date:  2010-10-27       Impact factor: 2.037

Review 2.  Systemic contact dermatitis and allergy to biomedical devices.

Authors:  Marcella Aquino; Tania Mucci
Journal:  Curr Allergy Asthma Rep       Date:  2013-10       Impact factor: 4.806

3.  Nickel-free stainless steel avoids neointima formation following coronary stent implantation.

Authors:  Katsuhito Fujiu; Ichiro Manabe; Makoto Sasaki; Motoki Inoue; Hiroshi Iwata; Eriko Hasumi; Issei Komuro; Yasuyuki Katada; Tetsushi Taguchi; Ryozo Nagai
Journal:  Sci Technol Adv Mater       Date:  2012-12-28       Impact factor: 8.090

Review 4.  Restenosis after PCI. Part 1: pathophysiology and risk factors.

Authors:  J Wouter Jukema; Jeffrey J W Verschuren; Tarek A N Ahmed; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2011-09-13       Impact factor: 32.419

5.  Coil embolization of intracranial saccular aneurysms using the Low-profile Visualized Intraluminal Support (LVIS™) device.

Authors:  Young Dae Cho; Chul-Ho Sohn; Hyun-Seung Kang; Jeong Eun Kim; Won-Sang Cho; Gyojun Hwang; O-Ki Kwon; Mi-Sun Ko; Nam-Mi Park; Moon Hee Han
Journal:  Neuroradiology       Date:  2014-04-17       Impact factor: 2.804

6.  Biological behaviour of human umbilical artery smooth muscle cell grown on nickel-free and nickel-containing stainless steel for stent implantation.

Authors:  Liming Li; Liwen An; Xiaohang Zhou; Shuang Pan; Xin Meng; Yibin Ren; Ke Yang; Yifu Guan
Journal:  Sci Rep       Date:  2016-01-04       Impact factor: 4.379

Review 7.  Inflammation as a determinant of healing response after coronary stent implantation.

Authors:  Dorota Ochijewicz; Mariusz Tomaniak; Grzegorz Opolski; Janusz Kochman
Journal:  Int J Cardiovasc Imaging       Date:  2021-01-21       Impact factor: 2.357

Review 8.  Hypersensitivity and in-stent restenosis in coronary stent materials.

Authors:  Wansong Hu; Jun Jiang
Journal:  Front Bioeng Biotechnol       Date:  2022-09-15

9.  Reduction of in-stent restenosis risk on nickel-free stainless steel by regulating cell apoptosis and cell cycle.

Authors:  Liming Li; Shuang Pan; Xiaohang Zhou; Xin Meng; Xiaoxi Han; Yibin Ren; Ke Yang; Yifu Guan
Journal:  PLoS One       Date:  2013-04-26       Impact factor: 3.240

10.  Relation of Nickel Allergy with in-Stent Restenosis in Patients Treated with Cobalt Chromium Stents.

Authors:  Cihangir Aliağaoğlu; Hakan Turan; Ismail Erden; Hülya Albayrak; Hakan Ozhan; Cengiz Başar; Zehra Gürlevik; Ayşegül Alçelik
Journal:  Ann Dermatol       Date:  2012-11-08       Impact factor: 1.444

  10 in total