Literature DB >> 19159809

Dispersive liquid-liquid microextraction preconcentration of palladium in water samples and determination by graphite furnace atomic absorption spectrometry.

Pei Liang1, Ehong Zhao, Feng Li.   

Abstract

A new method for the determination of palladium was developed by dispersive liquid-liquid microextraction preconcentration and graphite furnace atomic absorption spectrometry detection. In the proposed approach, diethyldithiocarbamate (DDTC) was used as a chelating agent, and carbon tetrachloride and ethanol were selected as extraction and dispersive solvent. Some factors influencing the extraction efficiency of palladium and its subsequent determination, including extraction and dispersive solvent type and volume, pH of sample solution, concentration of the chelating agent and extraction time, were studied and optimized. Under the optimum conditions, the enrichment factor of this method for palladium reached at 156. The detection limit for palladium was 2.4ngL(-1) (3sigma), and the relative standard deviation (R.S.D.) was 4.3% (n=7, c=1.0ngmL(-1)). The method was successfully applied to the determination of trace amount of palladium in water samples.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19159809     DOI: 10.1016/j.talanta.2008.10.033

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Cloud point extraction for the preconcentration of palladium and lead in environmental samples and determination by flow injection flame atomic absorption spectrometry: CPE for preconcentration of Pd and Pb by FI-FAAS.

Authors:  Dilek Bakircioglu
Journal:  Environ Sci Pollut Res Int       Date:  2012-01-25       Impact factor: 4.223

2.  Application of magnetic nanoparticles coated with sodium dodecyl sulfate and modified with 2-(5-bromo-2-pyridylazo)-5-diethyl aminophenol as a novel adsorbent for dispersive-magnetic solid-phase extraction and determination of palladium in soil samples.

Authors:  Meng Wang; Lan Wu; Qiufen Hu; Yaling Yang
Journal:  Environ Sci Pollut Res Int       Date:  2018-01-06       Impact factor: 4.223

3.  A New Ion-Imprinted Chitosan-Based Membrane with an Azo-Derivative Ligand for the Efficient Removal of Pd(II).

Authors:  Maria Pia Di Bello; Maria Rosaria Lazzoi; Giuseppe Mele; Sonia Scorrano; Lucia Mergola; Roberta Del Sole
Journal:  Materials (Basel)       Date:  2017-09-26       Impact factor: 3.623

Review 4.  Novel Approaches Utilizing Metal-Organic Framework Composites for the Extraction of Organic Compounds and Metal Traces from Fish and Seafood.

Authors:  Sofia C Vardali; Natalia Manousi; Mariusz Barczak; Dimitrios A Giannakoudakis
Journal:  Molecules       Date:  2020-01-24       Impact factor: 4.411

Review 5.  Application of hollow fiber liquid phase microextraction and dispersive liquid-liquid microextraction techniques in analytical toxicology.

Authors:  Vahid Sharifi; Ali Abbasi; Anahita Nosrati
Journal:  J Food Drug Anal       Date:  2016-01-07       Impact factor: 6.157

  5 in total