Literature DB >> 19159418

Extended storage of whole blood before the preparation of blood components: in vitro effects on red blood cells in Erythro-Sol environment.

H Gulliksson1, M Vesterinen, J-M Payrat, V Mayaudon.   

Abstract

BACKGROUND AND OBJECTIVES: Routine procedures for extended storage of whole blood (WB) before the preparation of blood components are of interest primarily for logistical reasons. We stored red cell units in either Erythro-Sol 2 (E-Sol 2, test units, 150 ml added) or in saline-adenine-glucose-mannitol (SAG-M) (reference units, 100 ml added) that were prepared after storage of WB at room temperature for 8, 12, 16 or 19 h after blood collection. STUDY DESIGN AND METHODS: Red blood cells were stored for 42 days. We measured pH, glucose, lactate, haemolysis, red blood cell adenosine triphosphate and 2,3-diphosphoglycerate on days 1, 7, 14, 21, 28, 35 and 42.
RESULTS: Haematocrits were significantly lower in E-Sol 2 than in SAG-M due to the higher volume of E-Sol 2 added compared to SAG-M. Significantly reduced levels were found in E-Sol 2 of extracellular pH (throughout storage after 8-h hold and initially after 12-, 16- or 19-h hold), of lactate (initially after 8-h hold and throughout storage after 12-, 16- or 19-h hold), and of haemolysis from day 35 in the 8-h and on day 42 in the 12-h hold group. Significantly increased levels of adenosine triphosphate were seen in E-Sol 2 after 8-h hold (from day 14) and after 12-h hold (at days 21, 35 and 42) compared to SAG-M. Significantly higher concentrations of 2,3-diphosphoglycerate were noticed primarily after 8-h hold of WB.
CONCLUSION: The use of E-Sol 2 as a replacement for SAG-M does not significantly improve in vitro data after extended storage of WB at room temperature before preparation of blood components. However, after 8-h hold in vitro characteristics similar to or better than in fresh blood will be maintained for several weeks in E-Sol 2, a situation that makes E-Sol 2 superior to SAG-M when storage of WB is limited to 8 h. Some improvement was noted after 12-h hold as well.

Entities:  

Mesh:

Year:  2009        PMID: 19159418     DOI: 10.1111/j.1423-0410.2008.01152.x

Source DB:  PubMed          Journal:  Vox Sang        ISSN: 0042-9007            Impact factor:   2.144


  1 in total

1.  Red cell storage: when is better not good enough?

Authors:  John R Hess
Journal:  Blood Transfus       Date:  2009-07       Impact factor: 3.443

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.