Abstract

BACKGROUND: Image-guided stereotaxy is a recent advancement in imaging technology, allowing computer guidance to aid surgical planning and accuracy. Despite the use of multiple techniques for patient registration in several surgical specialities, only fiducial marker registration has been described for use in soft tissue reconstructive surgery. The current study comprises an evaluation of the current techniques available for this purpose.
METHODS: A cohort of nine consecutive patients planned for elective free flaps were recruited, with the first five patients (four for the abdominal wall and one anterolateral thigh donor site) undergoing fiducial marker registration with a variable number of fiducial markers in order to determine the optimal number of fiducial markers to be used. Four subsequent patients undergoing perforator flap surgery underwent registration using three available registration modalities: fiducial marker registration, surface matching pointer/landmark and surface matching laser registration.
RESULTS: For the abdominal wall, registration was not able to be achieved with five fiducial markers, and was successfully achieved in all cases with either six or seven fiducial markers. For the anterolateral thigh, registration was achieved with either nine or ten markers. The four patients who also underwent surface-landmark registration and 'Z-touch' laser surface matching registration all failed the registration process.
CONCLUSION: Stereotactic navigation is a useful adjunct to the preoperative imaging of perforator flaps. Fiducial marker registration was able to be achieved in all cases, can be successfully achieved with a low and predictable number of fiducial markers, is highly accurate, and was the only reliable registration process in our experience.

Entities:  

Mesh:

Year:  2009        PMID: 19159056     DOI: 10.1007/s00276-008-0457-8

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  30 in total

1.  Development of computer-aided surgery for otorhinolaryngology.

Authors:  L Klimek; R Mösges; G Schlöndorff; W Mann
Journal:  Comput Aided Surg       Date:  1998

2.  Pioneers of stereotactic neurosurgery.

Authors:  N R al-Rodhan; P J Kelly
Journal:  Stereotact Funct Neurosurg       Date:  1992       Impact factor: 1.875

Review 3.  Reviewing the vascular supply of the anterior abdominal wall: redefining anatomy for increasingly refined surgery.

Authors:  W M Rozen; M W Ashton; G I Taylor
Journal:  Clin Anat       Date:  2008-03       Impact factor: 2.414

4.  History of functional neurosurgery.

Authors:  B J Iskandar; B S Nashold
Journal:  Neurosurg Clin N Am       Date:  1995-01       Impact factor: 2.509

5.  Interventional breast MR imaging: clinical use of a stereotactic localization and biopsy device.

Authors:  C K Kuhl; A Elevelt; C C Leutner; J Gieseke; E Pakos; H H Schild
Journal:  Radiology       Date:  1997-09       Impact factor: 11.105

6.  Comparison of the reliability of brain lesion localization when using traditional and stereotactic image-guided techniques: a prospective study.

Authors:  Carl J Spivak; Fahrad Pirouzmand
Journal:  J Neurosurg       Date:  2005-09       Impact factor: 5.115

7.  Electrical activity of subcortical areas in epilepsy.

Authors:  R A Hayne; L Belinson; F A Gibbs
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1949-11

8.  Fiducial versus nonfiducial neuronavigation registration assessment and considerations of accuracy.

Authors:  Wolfgang K Pfisterer; Stephen Papadopoulos; Denise A Drumm; Kris Smith; Mark C Preul
Journal:  Neurosurgery       Date:  2008-03       Impact factor: 4.654

9.  Application accuracy in frameless image-guided neurosurgery: a comparison study of three patient-to-image registration methods.

Authors:  Peter A Woerdeman; Peter W A Willems; Herke J Noordmans; Cornelis A F Tulleken; Jan Willem Berkelbach van der Sprenkel
Journal:  J Neurosurg       Date:  2007-06       Impact factor: 5.115

10.  Computer-assisted frameless stereotaxy in transsphenoidal surgery at a single institution: review of 176 cases.

Authors:  Jay Jagannathan; Daniel M Prevedello; Vivek S Ayer; Aaron S Dumont; John A Jane; Edward R Laws
Journal:  Neurosurg Focus       Date:  2006-02-15       Impact factor: 4.047

View more
  3 in total

Review 1.  A review of visualized preoperative imaging with a focus on surgical procedures of the breast.

Authors:  Bridget Rodkin; David J Hunter-Smith; Warren M Rozen
Journal:  Gland Surg       Date:  2019-10

2.  Quantitative regression analysis of the cutaneous vascular territories in a rat model.

Authors:  Youlun Tao; Siwang Hu; Koonhei W Lui; Shaohe Chen; Maolin Tang; Shixin Chen
Journal:  Surg Radiol Anat       Date:  2011-04-01       Impact factor: 1.246

3.  A mini pig model for visualization of perforator flap by using angiography and MIMICS.

Authors:  Jin Mei; ZhiXun Yin; Ji Zhang; Koonhei W Lui; Siwang Hu; Zhou Peng; Shixin Chen; Maolin Tang
Journal:  Surg Radiol Anat       Date:  2009-11-14       Impact factor: 1.246

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.