Literature DB >> 19158555

Agreement between stratus and visante optical coherence tomography systems in tear meniscus measurements.

Giacomo Savini1, Eiki Goto, Michele Carbonelli, Piero Barboni, David Huang.   

Abstract

AIM: To compare the tear meniscus height (TMH) measurements provided by the Stratus and Visante optical coherence tomography systems.
METHODS: A cross-section image of the lower tear meniscus was captured with both instruments in 26 volunteers. An external application was used to manually measure the TMH as imaged by the Stratus; measurements by the Visante were analyzed by the internal software. Only 1 eye for each subject was considered for statistical analysis.
RESULTS: The mean (+/-SD) TMH was higher when measured by the Visante (0.28 +/- 0.12 mm) compared with the Stratus (0.23 +/- 0.07 mm, P = 0.029). Measurements were correlated (R = 0.38, P = 0.0008), but Bland-Altman analysis showed low agreement (95% limits of agreement: -0.15 to +0.26 mm).
CONCLUSIONS: Visante and Stratus cannot be used interchangeably to measure the TMH. The differences between the 2 instruments are likely to be related both to the dynamic nature of the tear meniscus and to the distortion of Stratus images, which are not dewarped and calibrated for anterior segment imaging.

Mesh:

Year:  2009        PMID: 19158555     DOI: 10.1097/ICO.0b013e31818526d0

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  4 in total

1.  Is optical coherence tomography an effective device for evaluation of tear film meniscus in patients with acne rosacea?

Authors:  F C Eroglu; A Karalezli; R Dursun
Journal:  Eye (Lond)       Date:  2016-01-15       Impact factor: 3.775

2.  Correlation between optical coherence tomography-derived assessments of lower tear meniscus parameters and clinical features of dry eye disease.

Authors:  Pho Nguyen; David Huang; Yan Li; Srinivas R Sadda; Sylvia Ramos; Rajeev R Pappuru; Samuel C Yiu
Journal:  Cornea       Date:  2012-06       Impact factor: 2.651

3.  Automatic screening of tear meniscus from lacrimal duct obstructions using anterior segment optical coherence tomography images by deep learning.

Authors:  Hitoshi Imamura; Hitoshi Tabuchi; Daisuke Nagasato; Hiroki Masumoto; Hiroaki Baba; Hiroki Furukawa; Sachiko Maruoka
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-02-12       Impact factor: 3.117

Review 4.  A Review of Imaging Biomarkers of the Ocular Surface.

Authors:  William W Binotti; Betul Bayraktutar; M Cuneyt Ozmen; Stephanie M Cox; Pedram Hamrah
Journal:  Eye Contact Lens       Date:  2020-03       Impact factor: 3.152

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.