Literature DB >> 19157807

Direct detection of carcinoembryonic antigen autoantibodies in clinical human serum samples using a surface plasmon resonance sensor.

Jon Ladd1, Hailing Lu, Allen D Taylor, Vivian Goodell, Mary L Disis, Shaoyi Jiang.   

Abstract

The ability to detect biomarkers in human serum is important for cancer diagnostics. The work presented focuses on the establishment of a surface plasmon resonance (SPR) biosensor as a means for detecting varying levels of autoantibody biomarkers in human serum samples. Carcinoembryonic antigen (CEA) is a biomarker that is present in human serum. It is thought that CEA levels become elevated in patients with colon and ovarian cancer, causing a corresponding increase in the autoantibody level in human serum. Detection of this CEA autoantibody increase could be used to diagnose cancer in patients. Using a SPR biosensor, human serum samples were screened directly for CEA antibody levels. Results using a sandwich assay with a SPR sensor demonstrated the same linear trend as seen from an established enzyme-linked immunosorbent assay (ELISA) method. Serum samples from five healthy individuals were used to establish a threshold value for differentiating a cancerous serum sample from a negative sample with a 95% confidence. Three serum samples from cancer patients with positive CEA antibody levels as evaluated by ELISA were used to test the criterion.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19157807     DOI: 10.1016/j.colsurfb.2008.11.032

Source DB:  PubMed          Journal:  Colloids Surf B Biointerfaces        ISSN: 0927-7765            Impact factor:   5.268


  10 in total

1.  Protein analytical assays for diagnosing, monitoring, and choosing treatment for cancer patients.

Authors:  Alicia D Powers; Sean P Palecek
Journal:  J Healthc Eng       Date:  2012-12       Impact factor: 2.682

2.  Discovery and Validation of Agonistic Angiotensin Receptor Autoantibodies as Biomarkers of Adverse Outcomes.

Authors:  Peter M Abadir; Alka Jain; Laura J Powell; Qian-Li Xue; Jing Tian; Robert G Hamilton; David A Bennett; Thomas Finucane; Jeremy D Walston; Neal S Fedarko
Journal:  Circulation       Date:  2016-11-30       Impact factor: 29.690

3.  Changes of Serum Trace Elements, AFP, CEA, SF, T3, T4 and IGF-II in Different Periods of Rat Liver Cancer.

Authors:  Hong-Xu Zhang; Dan-Dan Liu; Bai-Jie Jin; Ya-Wei Wang; Qi Liu; Ru-Bing Duan; Peng Zhao; Ming-Xia Ma
Journal:  Chin J Cancer Res       Date:  2011-12       Impact factor: 5.087

4.  Development of a novel two dimensional surface plasmon resonance sensor using multiplied beam splitting optics.

Authors:  Akihide Hemmi; Ryosuke Mizumura; Ryuta Kawanishi; Hizuru Nakajima; Hulie Zeng; Katsumi Uchiyama; Noriaki Kaneki; Toshihiko Imato
Journal:  Sensors (Basel)       Date:  2013-01-08       Impact factor: 3.576

5.  Proteomic technologies for the study of osteosarcoma.

Authors:  Stephanie D Byrum; Charity L Washam; Corey O Montgomery; Alan J Tackett; Larry J Suva
Journal:  Sarcoma       Date:  2012-03-06

Review 6.  Choosing a suitable method for the identification of replication origins in microbial genomes.

Authors:  Chengcheng Song; Shaocun Zhang; He Huang
Journal:  Front Microbiol       Date:  2015-09-30       Impact factor: 5.640

Review 7.  Early lung cancer diagnosis by biosensors.

Authors:  Yuqian Zhang; Dongliang Yang; Lixing Weng; Lianhui Wang
Journal:  Int J Mol Sci       Date:  2013-07-25       Impact factor: 5.923

Review 8.  Recent advances in application of biosensors in tissue engineering.

Authors:  Anwarul Hasan; Md Nurunnabi; Mahboob Morshed; Arghya Paul; Alessandro Polini; Tapas Kuila; Moustafa Al Hariri; Yong-kyu Lee; Ayad A Jaffa
Journal:  Biomed Res Int       Date:  2014-08-06       Impact factor: 3.411

Review 9.  Screening and Biosensor-Based Approaches for Lung Cancer Detection.

Authors:  Lulu Wang
Journal:  Sensors (Basel)       Date:  2017-10-23       Impact factor: 3.576

Review 10.  Emerging microfluidic devices for cancer cells/biomarkers manipulation and detection.

Authors:  Victor Hugo Perez-Gonzalez; Roberto Carlos Gallo-Villanueva; Sergio Camacho-Leon; Jose Isabel Gomez-Quiñones; Jose Manuel Rodriguez-Delgado; Sergio Omar Martinez-Chapa
Journal:  IET Nanobiotechnol       Date:  2016-10       Impact factor: 1.847

  10 in total