Literature DB >> 19156892

Automated left ventricular delineation in X-ray angiograms: a validation study.

Elco Oost1, Pranobe Oemrawsingh, Johan H Reiber, Boudewijn Lelieveldt.   

Abstract

OBJECTIVES: Recently an automated analysis approach for left ventricular (LV) X-ray angiographic studies was proposed. This particular study aims to assess the clinical potential of this approach.
BACKGROUND: Over the past 30 years much research has been carried out to develop a technique with automated contour detection of the LV outline in the end-diastolic (ED) and end-systolic (ES) phases. Very few have made it into clinical practice. Our latest approach is based on innovative model-based image processing techniques.
METHODS: Two expert cardiologists analyzed 30 patient studies both by contouring the LV manually and by using the proposed automated methodology. In the latter procedure the experts were allowed to edit the automatically generated contours manually. The manual, automatic, and edited automatic contours were compared, focusing on accuracy, workflow efficiency, and inter- and intra-observer variabilities.
RESULTS: No significant differences between the automatically derived and manual LV volumes were observed. The average patient study analysis time was reduced by 26%, from 4.2 to 3.1 min. When editing was required, 19% of the ED and 25% of the ES contour length needed manual correction. Furthermore, a reduction in inter-observer variability of 12.4% was observed.
CONCLUSIONS: Using the proposed automated methodology for X-ray LV angiographic study analysis, a considerable reduction in required analysis time and manual effort is achieved. Because the acquired results are of clinically acceptable quality and the inter- and intra-observer variabilities are reduced, this automated approach has the potential to optimize the analysis workflow for LV X-ray angiography in clinical practice. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19156892     DOI: 10.1002/ccd.21672

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  From 4D Medical Images (CT, MRI, and Ultrasound) to 4D Structured Mesh Models of the Left Ventricular Endocardium for Patient-Specific Simulations.

Authors:  Federico Canè; Benedict Verhegghe; Matthieu De Beule; Philippe B Bertrand; Rob J Van der Geest; Patrick Segers; Gianluca De Santis
Journal:  Biomed Res Int       Date:  2018-01-08       Impact factor: 3.411

2.  Possible diverse contribution of coronary risk factors to left ventricular systolic and diastolic cavity sizes.

Authors:  Kenichiro Suzuki; Yasunori Inoue; Kazuo Ogawa; Tomohisa Nagoshi; Kosuke Minai; Takayuki Ogawa; Makoto Kawai; Michihiro Yoshimura
Journal:  Sci Rep       Date:  2021-01-15       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.