Literature DB >> 19156330

Determination and validation of six sunscreen agents in suncare products by UPLC and HPLC.

So-Mi Lee1, Hye-Jin Jeong, Ih Seop Chang.   

Abstract

Methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine are sunscreen agents that have hydrophobic behaviors in common. They were not normally assayed with the following four sunscreen agents that have hydrophilic behaviors in a single chromatographic run: ethylhexyl methoxycinnamate, isoamyl p-methoxycinnamate, ethylhexyl salicylate, and ethylhexyl triazone. For that reason, methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine require much time in order to assay products with those materials. A rapid, selective, and reproducible determination method needs to be developed for the simultaneous examination of methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine with the sunscreen agents, ethylhexyl methoxycinnamate, isoamyl p-methoxycinnamate, ethylhexyl salicylate, and ethylhexyl triazone. This new technique could reduce time in examining the sunscreen agents and be effective for quality control of suncare products. In this paper, the HPLC and UPLC system is used for developing the determination of the sunscreen agents. Several evaluations of some mixtures of eluents and columns were obtained for the optimal condition of separation. In HPLC, the optimal peak resolution was obtained through ethanol-water gradient elution and a 75-mm C18 column with a 3.5-microm-sized particle on a flow rate of 1.0 ml/min. In UPLC, the most distinctive peak resolution was obtained through methanol-water gradient elution and a 50-mm C18 column with a 1.7-microm-sized particle on a flow rate 0.4 ml/min. Both of those chromatographic determination methods could be used in the examination of six types of sunscreen agents without any interference from other product excipients in the agents. The proposed determination methods were validated for specificity, linearity, repeatability, system stability, intermediate precision, and accuracy. Consequently, HPLC and UPLC determination methods could be rapid, selective, and proper applications for the assay of sunscreen agents in suncare products.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19156330

Source DB:  PubMed          Journal:  J Cosmet Sci        ISSN: 1525-7886            Impact factor:   0.948


  3 in total

1.  Sensitive Synchronous Spectrofluorimetric Study of Certain Sunscreens Using Fluorescence Enhancers in Cosmeceutical Formulations.

Authors:  Maha F Abdel-Ghany; Miriam F Ayad; Neven N Mikawy
Journal:  J Fluoresc       Date:  2018-01-17       Impact factor: 2.217

2.  Quantification of sunscreen ethylhexyl triazone in topical skin-care products by normal-phase TLC/densitometry.

Authors:  Anna W Sobanska; Jaroslaw Pyzowski
Journal:  ScientificWorldJournal       Date:  2012-05-02

3.  Force degradation behavior of glucocorticoid deflazacort by UPLC: isolation, identification and characterization of degradant by FTIR, NMR and mass analysis.

Authors:  Rajesh Deshmukh; Lata Sharma; Muktika Tekade; Prashant Kesharwani; Piyush Trivedi; Rakesh K Tekade
Journal:  J Biomed Res       Date:  2016-02-20
  3 in total