Literature DB >> 19155153

Determination of impurities in heparin by capillary electrophoresis using high molarity phosphate buffers.

Todd Wielgos1, Karalyn Havel, Nadia Ivanova, Robert Weinberger.   

Abstract

Oversulfated chondroitin sulfate (OSCS), an impurity found in some porcine intestinal heparin samples was separated from intact heparin by capillary electrophoresis (CE) using a 600mM phosphate buffer, pH 3.5 as the background electrolyte in a 56cm x 25microm i.d. capillary. This method was confirmed in two separate labs, was shown to be linear, reproducible, robust, easy to use and provided the highest resolution and superior limits of detection compared to other available CE methods. Glycosoaminoglycans such as dermatan sulfate and heparan sulfate were separated and quantified as well during a single run. The heparin peak area response correlated well to values obtained using the official assay for biological activity. A high speed, high resolution version of the method was developed using 600mM lithium phosphate, pH 2.8 in a 21.5cm x 25microm i.d. capillary which provided limits of detection for OSCS that were below 0.1%.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19155153     DOI: 10.1016/j.jpba.2008.11.034

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  6 in total

Review 1.  Electrophoresis for the analysis of heparin purity and quality.

Authors:  Nicola Volpi; Francesca Maccari; Jiraporn Suwan; Robert J Linhardt
Journal:  Electrophoresis       Date:  2012-06       Impact factor: 3.535

2.  Mass balance analysis of contaminated heparin product.

Authors:  Zhenling Liu; Zhongping Xiao; Sayaka Masuko; Wenjing Zhao; Eric Sterner; Vinod Bansal; Jawed Fareed; Jonathan Dordick; Fuming Zhang; Robert J Linhardt
Journal:  Anal Biochem       Date:  2010-09-17       Impact factor: 3.365

3.  Highly sensitive potentiometric strip test for detecting high charge density impurities in heparin.

Authors:  Youngjea Kang; Kihak Gwon; Jae Ho Shin; Hakhyun Nam; Mark E Meyerhoff; Geun Sig Cha
Journal:  Anal Chem       Date:  2011-04-18       Impact factor: 6.986

4.  Orthogonal analytical approaches to detect potential contaminants in heparin.

Authors:  Marco Guerrini; Zhenqing Zhang; Zachary Shriver; Annamaria Naggi; Sayaka Masuko; Robert Langer; Benito Casu; Robert J Linhardt; Giangiacomo Torri; Ram Sasisekharan
Journal:  Proc Natl Acad Sci U S A       Date:  2009-09-23       Impact factor: 11.205

Review 5.  Analysis and characterization of heparin impurities.

Authors:  Szabolcs Beni; John F K Limtiaco; Cynthia K Larive
Journal:  Anal Bioanal Chem       Date:  2010-09-03       Impact factor: 4.142

Review 6.  Tools for the Quality Control of Pharmaceutical Heparin.

Authors:  Anthony Devlin; Courtney Mycroft-West; Patricia Procter; Lynsay Cooper; Scott Guimond; Marcelo Lima; Edwin Yates; Mark Skidmore
Journal:  Medicina (Kaunas)       Date:  2019-09-25       Impact factor: 2.430

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.