All-distance visual acuity and contrast visual acuity in eyes with a refractive multifocal intraocular lens with minimal added power.

Ken Hayashi1, Motoaki Yoshida, Hideyuki Hayashi.   

Abstract

PURPOSE: To compare visual acuity (VA) from far to near distances, photopic and mesopic contrast VA, and contrast VA in the presence of a glare source (glare VA), between eyes with a new refractive multifocal intraocular lens (IOL) with added power of only +3.0 diopters and those with a monofocal IOL.
DESIGN: Comparative, nonrandomized, interventional study. PARTICIPANTS: Forty-four eyes of 22 patients who were scheduled for implantation of a refractive multifocal IOL (Hoya SFX MV1; Tokyo, Japan) and 44 eyes of 22 patients scheduled for implantation of a monofocal IOL. INTERVENTION: All patients underwent phacoemulsification with bilateral implantation of either multifocal or monofocal IOLs. MAIN OUTCOME MEASURES: At approximately 3 months after surgery, monocular and binocular VA from far to near distances was measured using the all-distance vision tester (Kowa AS-15; Tokyo, Japan), whereas photopic and mesopic contrast VA and glare VA were examined using the Contrast Sensitivity Accurate Tester (Menicon CAT-2000, Nagoya, Japan). Pupillary diameter and the degree of IOL decentration and tilt were correlated with VA at all distances.
RESULTS: Mean VA in both the multifocal and monofocal IOL groups decreased gradually from far to near distances. When comparing the 2 groups, however, both uncorrected and best distance-corrected intermediate VA at 0.5 m and near VA at 0.3 m in the multifocal IOL group were significantly better than those in the monofocal IOL group (P<or=0.0037), although there was no significant difference in far VA or in intermediate VA at 0.7 and 1.0 m. Photopic and mesopic contrast VA and glare VA were similar between the 2 groups. In both the multifocal and monofocal IOL groups, no significant correlation was found between VA at any distance and pupillary diameter or between VA and the degree of IOL decentration and tilt.
CONCLUSIONS: A new refractive multifocal IOL with minimal added power provides significantly better intermediate and near VA than does a monofocal IOL; contrast VA and glare VA are not impaired with this multifocal IOL. Visual acuity at all distances with this IOL is not correlated with pupillary diameter or with IOL decentration and tilt.

Entities:  

Mesh:

Year:  2009        PMID: 19152978     DOI: 10.1016/j.ophtha.2008.09.052

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  6 in total

Review 1.  Multifocal versus monofocal intraocular lenses after cataract extraction.

Authors:  Samantha R de Silva; Jennifer R Evans; Varo Kirthi; Mohammed Ziaei; Martin Leyland
Journal:  Cochrane Database Syst Rev       Date:  2016-12-12

2.  Evaluation of contrast visual acuity in patients with retinitis pigmentosa.

Authors:  Kazumi Oomachi; Kazuha Ogata; Takeshi Sugawara; Akira Hagiwara; Akira Hata; Shuichi Yamamoto
Journal:  Clin Ophthalmol       Date:  2011-10-11

3.  Comparative Analysis of Visual Performance and Optical Quality with a Rotationally Asymmetric Multifocal Intraocular Lens and an Apodized Diffractive Multifocal Intraocular Lens.

Authors:  Xiao Wang; Haixia Tu; Yong Wang
Journal:  J Ophthalmol       Date:  2020-04-20       Impact factor: 1.909

Review 4.  Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations.

Authors:  Zahra Ashena; Sundas Maqsood; Syed Naqib Ahmed; Mayank A Nanavaty
Journal:  Vision (Basel)       Date:  2020-09-14

5.  Femtosecond laser-assisted cataract surgery after corneal refractive surgery.

Authors:  Hyunmin Ahn; Ikhyun Jun; Kyoung Yul Seo; Eung Kweon Kim; Tae-Im Kim
Journal:  Sci Rep       Date:  2022-03-11       Impact factor: 4.379

6.  Visual Performances of a New Extended Depth-of-Focus Intraocular Lens with a Refractive Design: A Prospective Study After Bilateral Implantation.

Authors:  Leopoldo Spadea; Maria Ilaria Giannico; Martina Formisano; Ludovico Alisi
Journal:  Ther Clin Risk Manag       Date:  2021-07-16       Impact factor: 2.423

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.