Literature DB >> 19152616

Biomechanical comparison of two alternative tibial plateau leveling osteotomy plates with the original standard in an axially loaded gap model: an in vitro study.

Paul A Kloc1, Michael P Kowaleski, Alan S Litsky, Nancy O Brown, Kenneth A Johnson.   

Abstract

OBJECTIVE: To compare the axial compression stiffness of osteotomized canine tibiae stabilized with Slocum, Securos, or Synthes plates after a tibial plateau leveling osteotomy (TPLO) procedure. STUDY
DESIGN: In vitro, paired comparison of cadaveric tibial constructs subjected to mechanical testing under an axial load. SAMPLE POPULATION: Canine tibiae (n=16 pairs) from skeletally mature male and female dogs of various breeds (18-55 kg).
METHODS: Tibial pairs (n=16) were randomly assigned to 1 of 2 study cohorts (n=8 pairs/cohort): cohort 1, tibial osteotomy stabilization with a Slocum or a Securos plate, or cohort 2, tibial osteotomy stabilization with a Slocum or a Synthes plate. One tibia from each pair was stabilized with 1 of each plate design assigned to the cohort after TPLO. A 3.2 mm osteotomy gap was maintained during plate application in all constructs. Load and axial displacement were recorded while constructs were loaded to 2000 N in axial compression. Failure loads were not reported because no distinct yield point or failure point was evident within the load range for many specimens. Failure modes were recorded for each construct, and photographs of typical failures were obtained. Stiffness (N/mm) was calculated from load-displacement curves. Paired comparisons of mean stiffness were performed within study groups using a paired t-test. Significance was set at P<.05.
RESULTS: The mean construct stiffnesses for the Slocum (383+/-183 N/mm) and Securos (258+/-64.1 N/mm) constructs were not significantly different (P=.164; power=0.566). The mean construct stiffness for the Synthes constructs (486+/-91.0 N/mm) was significantly greater than that of the Slocum constructs (400+/-117 N/mm); P=.0468. Modes of failure for the Slocum (16/16) and Securos (8/8) constructs included plastic deformation of the implant with valgus deformity combined with fibular luxation (2/16 Slocum; 1/8 Securos) or fibular fracture (2/16 Slocum; 4/8 Securos). Most Synthes constructs underwent elastic deformation (7/8). One Synthes construct fractured in the sagittal plane through the tibial plateau depression at the point of load application.
CONCLUSIONS: The Slocum and Securos plate/tibia construct have similar stiffness, whereas the Synthes/tibia constructs are significantly stiffer than the Slocum/tibia constructs. Modes of fixation failure observed in this model were consistent with TPLO fixation failures observed clinically. CLINICAL RELEVANCE: Construct stiffness in axial load varies with implant type. Implants that confer higher stiffness to the construct may result in greater fixation stability in tibial metaphyseal osteotomies.

Entities:  

Mesh:

Year:  2009        PMID: 19152616     DOI: 10.1111/j.1532-950X.2008.00464.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  4 in total

1.  Construction and biomechanical properties of polyaxial self-locking anatomical plate based on the geometry of distal tibia.

Authors:  Weiguo Liang; Weixiong Ye; Dongping Ye; Ziqiang Zhou; Zhiguang Chen; Aiguo Li; Zong-Han Xie; Lihai Zhang; Jiake Xu
Journal:  Biomed Res Int       Date:  2014-06-16       Impact factor: 3.411

Review 2.  Tibial Plateau Leveling Osteotomy for Cranial Cruciate Ligament Rupture in Canines: Patient Selection and Reported Outcomes.

Authors:  Andy Nanda; Eric C Hans
Journal:  Vet Med (Auckl)       Date:  2019-12-27

3.  Efficacy of a Customized Three-Dimensional Printing Surgical Guide for Tibial Plateau Leveling Osteotomy: A Comparison With Conventional Tibial Plateau Leveling Osteotomy.

Authors:  Jayon Kim; Jaeeun Ko; Jaehwan Kim; Anna Seo; Kidong Eom
Journal:  Front Vet Sci       Date:  2021-11-25

4.  Long-term outcome of tibial plateau leveling osteotomy using an antimicrobial silver-based coated plate in dogs.

Authors:  Geoffrey Pagès; Meike Hammer; Jean-Guillaume Grand; Iban Irubetagoyena
Journal:  PLoS One       Date:  2022-08-12       Impact factor: 3.752

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.