Literature DB >> 19152368

On the inter-instrument and the inter-laboratory transferability of a tandem mass spectral reference library: 2. Optimization and characterization of the search algorithm.

Herbert Oberacher1, Marion Pavlic, Kathrin Libiseller, Birthe Schubert, Michael Sulyok, Rainer Schuhmacher, Edina Csaszar, Harald C Köfeler.   

Abstract

A sophisticated matching algorithm developed for highly efficient identity search within tandem mass spectral libraries is presented. For the optimization of the search procedure a collection of 410 tandem mass spectra corresponding to 22 compounds was used. The spectra were acquired in three different laboratories on four different instruments. The following types of tandem mass spectrometric instruments were used: quadrupole-quadrupole-time-of-flight (QqTOF), quadrupole-quadrupole-linear ion trap (QqLIT), quadrupole-quadrupole-quadrupole (QqQ), and linear ion trap-Fourier transform ion cyclotron resonance mass spectrometer (LIT-FTICR). The obtained spectra were matched to an established MS/MS-spectral library that contained 3759 MS/MS-spectra corresponding to 402 different reference compounds. All 22 test compounds were part of the library. A dynamic intensity cut-off, the search for neutral losses, and optimization of the formula used to calculate the match probability were shown to significantly enhance the performance of the presented library search approach. With the aid of these features the average number of correct assignments was increased to 98%. For statistical evaluation of the match reliability the set of fragment ion spectra was extended with 300 spectra corresponding to 100 compounds not included in the reference library. Performance was checked with the aid of receiver operating characteristic (ROC) curves. Using the magnitude of the match probability as well as the precursor ion mass as benchmarks to rate the obtained top hit, overall correct classification of a compound being included or not included in the mass spectrometric library, was obtained in more than 95% of cases clearly indicating a high predictive accuracy of the established matching procedure. Copyright (c) 2009 John Wiley & Sons, Ltd.

Mesh:

Year:  2009        PMID: 19152368     DOI: 10.1002/jms.1525

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  13 in total

1.  Automatic Compound Annotation from Mass Spectrometry Data Using MAGMa.

Authors:  Lars Ridder; Justin J J van der Hooft; Stefan Verhoeven
Journal:  Mass Spectrom (Tokyo)       Date:  2014-07-02

2.  Calculation of retention time tolerance windows with absolute confidence from shared liquid chromatographic retention data.

Authors:  Paul G Boswell; Daniel Abate-Pella; Joshua T Hewitt
Journal:  J Chromatogr A       Date:  2015-08-01       Impact factor: 4.759

3.  Analytical Validation of a Portable Mass Spectrometer Featuring Interchangeable, Ambient Ionization Sources for High Throughput Forensic Evidence Screening.

Authors:  Zachary E Lawton; Angelica Traub; William L Fatigante; Jose Mancias; Adam E O'Leary; Seth E Hall; Jamie R Wieland; Herbert Oberacher; Michael C Gizzi; Christopher C Mulligan
Journal:  J Am Soc Mass Spectrom       Date:  2016-12-20       Impact factor: 3.109

4.  Performance evaluation of three liquid chromatography mass spectrometry methods for broad spectrum drug screening.

Authors:  Kara L Lynch; Autumn R Breaud; Hilde Vandenberghe; Alan H B Wu; William Clarke
Journal:  Clin Chim Acta       Date:  2010-06-09       Impact factor: 3.786

Review 5.  Identification of small molecules using accurate mass MS/MS search.

Authors:  Tobias Kind; Hiroshi Tsugawa; Tomas Cajka; Yan Ma; Zijuan Lai; Sajjan S Mehta; Gert Wohlgemuth; Dinesh Kumar Barupal; Megan R Showalter; Masanori Arita; Oliver Fiehn
Journal:  Mass Spectrom Rev       Date:  2017-04-24       Impact factor: 10.946

6.  Advances in structure elucidation of small molecules using mass spectrometry.

Authors:  Tobias Kind; Oliver Fiehn
Journal:  Bioanal Rev       Date:  2010-08-21

7.  Applying Tandem Mass Spectral Libraries for Solving the Critical Assessment of Small Molecule Identification (CASMI) LC/MS Challenge 2012.

Authors:  Herbert Oberacher
Journal:  Metabolites       Date:  2013-04-26

8.  Studying the reducing potencies of antioxidants with the electrochemistry inherently present in electrospray ionization-mass spectrometry.

Authors:  Sabine Plattner; Robert Erb; Jean-Pierre Chervet; Herbert Oberacher
Journal:  Anal Bioanal Chem       Date:  2013-11-08       Impact factor: 4.142

9.  Computational mass spectrometry for small molecules.

Authors:  Kerstin Scheubert; Franziska Hufsky; Sebastian Böcker
Journal:  J Cheminform       Date:  2013-03-01       Impact factor: 5.514

10.  Metabolite identification through multiple kernel learning on fragmentation trees.

Authors:  Huibin Shen; Kai Dührkop; Sebastian Böcker; Juho Rousu
Journal:  Bioinformatics       Date:  2014-06-15       Impact factor: 6.937

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.