Magnetic distortion in motion labs, implications for validating inertial magnetic sensors.

W H K de Vries1, H E J Veeger, C T M Baten, F C T van der Helm.   

Abstract

BACKGROUND: Ambulatory 3D orientation estimation with Inertial Magnetic Sensor Units (IMU's) use the earth magnetic field. The magnitude of distortion in orientation in a standard equipped motion lab and its effect on the accuracy of the orientation estimation with IMU's is addressed.
METHODS: Orientations of the earth magnetic field vectors were expressed in the laboratory's reference frame. The effect of a distorted earth magnetic field on orientation estimation with IMU's (using both a quaternion and a Kalman fusing algorithm) was compared to orientations derived from an optical system.
FINDINGS: The magnetic field varied considerably, with the strongest effects at 5 cm above floor level with a standard deviation in heading of 29 degrees , decreasing to 3 degrees at levels higher than 100 cm. Orientation estimation was poor with the quaternion filter, for the Kalman filter results were acceptable, despite a systematic deterioration over time (after 20-30s).
INTERPRETATION: Distortion of the earth magnetic field is depending on construction materials used in the building, and should be taken into account for calibration, alignment to a reference system, and further measurements. Mapping the measurement volume to determine its ferromagnetic characteristics in advance of planned experiments can be the rescue of the data set.
CONCLUSIONS: To obtain valid data, "mapping" of the laboratory is essential, although less critical with the Kalman filter and at larger distances (>100 cm) from suspect materials. Measurements should start in a "safe" area and continue no longer than 20-30s in a heavily distorted earth magnetic field.

Mesh:

Year:  2009        PMID: 19150239     DOI: 10.1016/j.gaitpost.2008.12.004

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  52 in total

1.  First in vivo assessment of "Outwalk": a novel protocol for clinical gait analysis based on inertial and magnetic sensors.

Authors:  Alberto Ferrari; Andrea Giovanni Cutti; Pietro Garofalo; Michele Raggi; Monique Heijboer; Angelo Cappello; Angelo Davalli
Journal:  Med Biol Eng Comput       Date:  2009-11-13       Impact factor: 2.602

2.  3D spinal motion analysis during staircase walking using an ambulatory inertial and magnetic sensing system.

Authors:  Jung Keun Lee; Edward J Park
Journal:  Med Biol Eng Comput       Date:  2011-01-27       Impact factor: 2.602

3.  An enactive approach to appropriation in the instrumented activity of trail running.

Authors:  Nadège Rochat; Ludovic Seifert; Brice Guignard; Denis Hauw
Journal:  Cogn Process       Date:  2019-06-01

4.  Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis.

Authors:  Xavier Robert-Lachaine; Hakim Mecheri; Christian Larue; André Plamondon
Journal:  Med Biol Eng Comput       Date:  2016-07-05       Impact factor: 2.602

5.  Estimating dynamic gait stability using data from non-aligned inertial sensors.

Authors:  Sjoerd M Bruijn; Warner R Th Ten Kate; Gert S Faber; Onno G Meijer; Peter J Beek; Jaap H van Dieën
Journal:  Ann Biomed Eng       Date:  2010-03-31       Impact factor: 3.934

Review 6.  Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review.

Authors:  Valentina Camomilla; Elena Bergamini; Silvia Fantozzi; Giuseppe Vannozzi
Journal:  Sensors (Basel)       Date:  2018-03-15       Impact factor: 3.576

7.  Prediction of lower limb joint angles and moments during gait using artificial neural networks.

Authors:  Marion Mundt; Wolf Thomsen; Tom Witter; Arnd Koeppe; Sina David; Franz Bamer; Wolfgang Potthast; Bernd Markert
Journal:  Med Biol Eng Comput       Date:  2019-12-11       Impact factor: 2.602

8.  Can a rescuer or simulated patient accurately assess motion during cervical spine stabilization practice sessions?

Authors:  Ian Shrier; Patrick Boissy; Simon Brière; Jay Mellette; Luc Fecteau; Gordon O Matheson; Daniel Garza; Willem H Meeuwisse; Eli Segal; John Boulay; Russell J Steele
Journal:  J Athl Train       Date:  2012 Jan-Feb       Impact factor: 2.860

9.  Gait analysis in children with cerebral palsy via inertial and magnetic sensors.

Authors:  Josien C van den Noort; Alberto Ferrari; Andrea G Cutti; Jules G Becher; Jaap Harlaar
Journal:  Med Biol Eng Comput       Date:  2012-12-09       Impact factor: 2.602

10.  Ambulatory human motion tracking by fusion of inertial and magnetic sensing with adaptive actuation.

Authors:  H Martin Schepers; Daniel Roetenberg; Peter H Veltink
Journal:  Med Biol Eng Comput       Date:  2009-12-17       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.