Marginal adaptation in vitro and clinical outcome of Class V restorations.

S D Heintze1, U Blunck, T N Göhring, V Rousson.   

Abstract

OBJECTIVES: We examined the correlation between the quantitative margin analysis of two laboratory test methods (Berlin, Zurich) and the clinical outcome in Class V restorations.
METHODS: Prospective clinical studies with an observation period of at least 18 months were searched in the literature, for which laboratory data were also available. The clinical outcome variables were retention loss, marginal discoloration, detectable margins and secondary caries. Forty-four clinical studies matched the inclusion criteria, including 34 adhesive systems for which laboratory data were also present. For both laboratory test methods and the clinical studies, an index was formulated to better compare the in vitro and in vivo results. Linear mixed models which included a random study effect were calculated. As most clinical data were available for 12 and 24 months, the main analysis was restricted to these recall intervals.
RESULTS: The comparative analysis revealed a weak correlation between the clinical index and both in vitro indices. The correlation was statistically significant for the Berlin method but not for the Zurich method and only present if studies were compared which used the same composite in the in vitro and in vivo study. When defining specific cut-off values, the prognosis for the good clinical performance of an adhesive system based on in vitro results was 78% (Berlin) or 100% (Zurich). For poor performance it was 67% and 60%, respectively. No correlation was found between both in vitro methods. SIGNIFICANCE: The surrogate parameter "marginal adaptation" of restorations placed in extracted teeth has a mediocre value to predict the clinical performance of an adhesive system in cervical cavities. The composite is an important factor for a successful prediction. The comparison between in vitro/in vivo is sometimes hampered by the great variability of clinical results on the same adhesive system.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19147216     DOI: 10.1016/j.dental.2008.11.004

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  6 in total

1.  The influence of FRCs reinforcement on marginal adaptation of CAD/CAM composite resin endocrowns after simulated fatigue loading.

Authors:  Giovanni Tommaso Rocca; Carlo Massimo Saratti; Antoine Poncet; Albert J Feilzer; Ivo Krejci
Journal:  Odontology       Date:  2015-04-09       Impact factor: 2.634

2.  Self-etching aspects of a three-step etch-and-rinse adhesive.

Authors:  Jose Bahillo; Miguel Roig; Tissiana Bortolotto; Ivo Krejci
Journal:  Clin Oral Investig       Date:  2012-11-10       Impact factor: 3.573

3.  An in vitro evaluation of microleakage in class V preparations restored with Hybrid versus Silorane composites.

Authors:  Fahad Umer; Farah Naz; Farhan Raza Khan
Journal:  J Conserv Dent       Date:  2011-04

4.  Comparative evaluation of shear bond strength and nanoleakage of conventional and self-adhering flowable composites to primary teeth dentin.

Authors:  Priyanka Sachdeva; Mousumi Goswami; Darrel Singh
Journal:  Contemp Clin Dent       Date:  2016 Jul-Sep

5.  A retrospective multicenter study comparing metal-ceramic and composite single crowns performed in public general dentistry: 5-year results.

Authors:  Jennie Overmeer; Birger Narby; Lars Hjalmarsson; Kristina Arnrup; Alf Eliasson
Journal:  Acta Biomater Odontol Scand       Date:  2016-02-01

6.  Investigations on the adhesion of new composites for restoring cervical lesions using energy dispersive X-ray analysis and scanning electron microscopy.

Authors:  Alexandra Roman; Stefan Ioan Stratul; Darian Rusu; Marius Boariu; Andrada Soanca; Robert Balazsi; Maria Suciu; Mărioara Moldovan; Adriana Elena Bulboacă
Journal:  Sci Rep       Date:  2019-07-08       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.