Literature DB >> 19143701

The TEG vs the ROTEM thromboelastography/thromboelastometry systems.

G N B Jackson1, K J Ashpole, S M Yentis.   

Abstract

We have evaluated the TEG thromboelastograph and the ROTEM thromboelastometer, two point-of-care devices that measure blood coagulation. During a one-week period, seven consultant anaesthetists, one consultant haematologist, one associate specialist anaesthetist and two senior trainee anaesthetists were trained by the manufacturers and set up, calibrated and used both systems, after which their views were obtained and specific technical/support information was sought from the manufacturers using a questionnaire. Although the devices shared common features, they differed in complexity and aspects of ease of use, and in their purchase and running costs.

Entities:  

Mesh:

Year:  2009        PMID: 19143701     DOI: 10.1111/j.1365-2044.2008.05752.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  16 in total

Review 1.  An introduction to point-of-care testing in extracorporeal circulation and LVADs.

Authors:  Rachel Sara Bercovitz
Journal:  Hematology Am Soc Hematol Educ Program       Date:  2018-11-30

2.  Goal-directed coagulation management of major trauma patients using thromboelastometry (ROTEM)-guided administration of fibrinogen concentrate and prothrombin complex concentrate.

Authors:  Herbert Schöchl; Ulrike Nienaber; Georg Hofer; Wolfgang Voelckel; Csilla Jambor; Gisela Scharbert; Sibylle Kozek-Langenecker; Cristina Solomon
Journal:  Crit Care       Date:  2010-04-07       Impact factor: 9.097

Review 3.  Microfluidics and coagulation biology.

Authors:  Thomas V Colace; Garth W Tormoen; Owen J T McCarty; Scott L Diamond
Journal:  Annu Rev Biomed Eng       Date:  2013-05-03       Impact factor: 9.590

Review 4.  Differences in platelet aggregometers to study platelet function and coagulation dysregulation in xenotransplantation.

Authors:  Abdulkadir Isidan; Angela M Chen; Kutay Saglam; Sezai Yilmaz; Wenjun Zhang; Ping Li; Burcin Ekser
Journal:  Xenotransplantation       Date:  2020-09-18       Impact factor: 3.907

5.  Case Report: Rotational Thromboelastometry in Taipan Envenomation.

Authors:  Catherine L Tacon; Azhar Munas; Mark Little
Journal:  Am J Trop Med Hyg       Date:  2021-11-01       Impact factor: 2.345

6.  Thromboelastometry-guided blood transfusion in septic shock complicated with disseminated intravascular coagulation: a case report.

Authors:  Tomaz Crochemore; Flavia Nunes Dias Campos; Camila Menezes Souza Pessoa; Leonardo Lima Rocha; Pedro Paulo Zanella do Amaral Campos; Thiago Domingos Corrêa
Journal:  Clin Case Rep       Date:  2017-03-31

7.  Thromboelastometry versus standard coagulation tests versus restrictive protocol to guide blood transfusion prior to central venous catheterization in cirrhosis: study protocol for a randomized controlled trial.

Authors:  Leonardo Lima Rocha; Camila Menezes Souza Pessoa; Ary Serpa Neto; Rogerio Ruscitto do Prado; Eliezer Silva; Marcio Dias de Almeida; Thiago Domingos Correa
Journal:  Trials       Date:  2017-02-27       Impact factor: 2.279

8.  Microrheometer for Biofluidic Analysis: Electronic Detection of the Fluid-Front Advancement.

Authors:  Lourdes Méndez-Mora; Maria Cabello-Fusarés; Josep Ferré-Torres; Carla Riera-Llobet; Samantha Lopez; Claudia Trejo-Soto; Tomas Alarcón; Aurora Hernandez-Machado
Journal:  Micromachines (Basel)       Date:  2021-06-20       Impact factor: 2.891

9.  TEG® and ROTEM® in trauma: similar test but different results?

Authors:  Ajith Sankarankutty; Bartolomeu Nascimento; Luis Teodoro da Luz; Sandro Rizoli
Journal:  World J Emerg Surg       Date:  2012-08-22       Impact factor: 5.469

Review 10.  Biomechanics of haemostasis and thrombosis in health and disease: from the macro- to molecular scale.

Authors:  Reginald Tran; David R Myers; Jordan Ciciliano; Elaissa L Trybus Hardy; Yumiko Sakurai; Byungwook Ahn; Yongzhi Qiu; Robert G Mannino; Meredith E Fay; Wilbur A Lam
Journal:  J Cell Mol Med       Date:  2013-03-14       Impact factor: 5.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.