Literature DB >> 19141047

The effect of engaging the screw access channel of an implant abutment with a cement-retained restoration.

Supritha Naik1, Christopher J Tredwin, Michael Nesbit, Derrick J Setchell, David R Moles.   

Abstract

PURPOSE: Factors affecting the retention of fixed prostheses to natural abutments are well understood. In contrast, little is known concerning the factors influencing the retention of fixed prostheses cemented to implant abutments. The purpose of this study was to investigate the effect that extending a casting into the screw access channel of an implant abutment has on the retention when cemented using Temp Bond.
MATERIALS AND METHODS: Replace Select Straight abutments received set modifications (buccal wall removal at 15 degrees , 22 degrees , and 30 degrees ) using a milling machine; controls were unmodified. Two castings were fabricated for each of the modified abutments, one with and one without an extension into the screw access channel. Following cementation with Temp Bond under standardized conditions, the castings were removed from the abutments using an Instron machine, and the peak removal force was recorded.
RESULTS: Extending the casting into the screw access channel significantly (p < 0.001) increased the peak load of removal. Significant differences (p < 0.05) were found between no modification and 30 degrees modification, 15 degrees and 30 degrees modification, and 22 degrees and 30 degrees modification in the groups when the casting extended into the abutment. In the group where the casting did not extend into the abutment, all groups were significantly different (p < 0.001) with the exception of 22 degrees and 30 degrees modification.
CONCLUSIONS: The increased load required to remove a casting that extends into the screw access channel of an implant abutment may compensate for loss in retention, which occurs through unfavorable modification of the abutment.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19141047     DOI: 10.1111/j.1532-849X.2008.00408.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  7 in total

1.  Evaluation of the Effect of Axial Wall Modification and Coping Design on the Retention of Cement-retained Implant-supported Crowns.

Authors:  Reza Derafshi; Ahmad Hasan Ahangari; Kianoosh Torabi; Mitra Farzin
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2015-03-04

2.  Effect of abutment modification and cement type on retention of cement-retained implant supported crowns.

Authors:  Mitra Farzin; Kianoosh Torabi; Ahmad Hasan Ahangari; Reza Derafshi
Journal:  J Dent (Tehran)       Date:  2014-05-31

3.  Effect of Surface Modifications on the Retention of Cement-retained Implant Crowns under Fatigue Loads: An In vitro Study.

Authors:  R Ajay; K Suma; Seyed Asharaf Ali; Jambai Sampath Kumar Sivakumar; V Rakshagan; V Devaki; K Divya
Journal:  J Pharm Bioallied Sci       Date:  2017-11

4.  Effect of Implant Abutment Acid Etching on the Retention of Crowns Luted with Different Cements: An In Vitro Comparative Evaluation.

Authors:  R Ajay; V Rakshagan; M Kamatchi; A SelvaBalaji; Jambai Sampath Kumar Sivakumar; M Senthil Kumar
Journal:  J Pharm Bioallied Sci       Date:  2019-05

5.  An In Vitro Trial to Estimate the Retention Ability of Luting Agents Utilized with Dental Implant-Supported Prosthesis.

Authors:  Aasia Ahsan; B Khushboo; Ashish Kumar; Sweta Kumari; Bharathi Poojary; Arti Dixit; Amit Kumar; Bhumika Kamal Badiyani
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13

6.  Effect of surface treatments on the retention of implant-supported cement-retained bridge with short abutments: An in vitro comparative evaluation.

Authors:  Monica Shrivastav
Journal:  J Indian Prosthodont Soc       Date:  2018 Apr-Jun

7.  In Vitro Impact Testing to Simulate Implant-Supported Prosthesis Retrievability in Clinical Practice: Influence of Cement and Abutment Geometry.

Authors:  Andrea T Lugas; Mara Terzini; Elisabetta M Zanetti; Gianmario Schierano; Carlo Manzella; Domenico Baldi; Cristina Bignardi; Alberto L Audenino
Journal:  Materials (Basel)       Date:  2020-04-09       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.