Literature DB >> 19138850

Transcranial Doppler study of cerebral arteriovenous malformations after gamma knife radiosurgery.

Seong-Hyun Park1, Sung-Kyoo Hwang.   

Abstract

The aim of this study was to evaluate the clinical value of the Transcranial Doppler (TCD) in follow-up examinations after gamma knife radiosurgery (GKS) for arteriovenous malformations (AVM). We performed TCD after GKS in 18 patients who had cerebral AVMs to evaluate the hemodynamic effects of the procedure. Ten patients underwent TCD within 12 months after GKS, and eight between 12 and 24 months. The mean blood velocity (Vm) and pulsatility index (PI) were primarily analyzed in the feeding arteries (FAs) and non-FAs. Fifteen healthy volunteers served as control patients. The Vm values in the FAs after GKS ranged from 31 cm/s to 90 cm/s, with PI values ranging from 0.48 to 1.03. The Vm values in the comparable normal arteries ranged from 28 cm/s to 87 cm/s, and the PI values in these arteries ranged from 0.62 to 1.02. The Vm and PI values in every FA in all patients were normal compared to the values in the non-FAs (p=0.67 and 0.38, respectively). Our results suggest that AVM vessels with high Vm and low PI values return to normal as the nidus of the AVM is obliterated after GKS. Although there was a trend toward a reduction of the Vm values after obliteration, this trend was not significant, except when the < 12 month subgroup was compared to the 12-24 month subgroup. In our limited study, TDC proved to be a reliable, safe and non-invasive method to monitor the outcome of GKS for cerebral AVMs.

Entities:  

Mesh:

Year:  2009        PMID: 19138850     DOI: 10.1016/j.jocn.2008.04.025

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  3 in total

Review 1.  Transcranial Doppler ultrasound: a review of the physical principles and major applications in critical care.

Authors:  Jawad Naqvi; Kok Hooi Yap; Gulraiz Ahmad; Jonathan Ghosh
Journal:  Int J Vasc Med       Date:  2013-12-12

2.  Quantification of blood flow in internal cerebral artery by optical flow method on digital subtraction angiography in comparison with time-of-flight magnetic resonance angiography.

Authors:  Tzung-Chi Huang; Chih-Kai Chang; Chun-Han Liao; Yung-Jen Ho
Journal:  PLoS One       Date:  2013-01-24       Impact factor: 3.240

3.  Ascertaining the Value of Noninvasive Measures Obtained Using Color Duplex Ultrasound and Central Aortic Pressure Monitoring During the Management of Cerebral Arteriovenous Malformation Resection: Protocol for a Prospective, Case Control Pilot Study.

Authors:  Kathryn J Busch; Hosen Kiat
Journal:  JMIR Res Protoc       Date:  2017-08-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.