Literature DB >> 19137161

Field comparison of passive air samplers with reference monitors for ambient volatile organic compounds and nitrogen dioxide under week-long integrals.

Shaibal Mukerjee1, Karen D Oliver, Robert L Seila, Henry H Jacumin, Carry Croghan, E Hunter Daughtrey, Lucas M Neas, Luther A Smith.   

Abstract

This study evaluates performance of nitrogen dioxide (NO2) and volatile organic compound (VOC) passive samplers with corresponding reference monitors at two sites in the Detroit, Michigan area during the summer of 2005. Ogawa passive NO2 samplers and custom-made, re-useable Perkin-Elmer (PE) tubes with Carbopack X sorbent for VOCs were deployed under week-long sampling periods for six weeks. Precise results (5% relative standard deviation, RSD) were found for NO2 measurements from collocated Ogawa samplers. Reproducibility was also good for duplicate PE tubes for benzene, toluene, ethylbenzene, and xylene isomers (BTEX species, all < or = 6% RSD). As seen in previous studies, comparison of Ogawa NO2 samplers with reference chemiluminescence measurements suggested good agreement. Generally good agreement was also found between the PE tubes and reference methods for BTEX species.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19137161     DOI: 10.1039/b809588d

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  8 in total

1.  Sample integrity evaluation and EPA method 325B interlaboratory comparison for select volatile organic compounds collected diffusively on Carbopack X sorbent tubes.

Authors:  Karen D Oliver; Tamira A Cousett; Donald A Whitaker; Luther A Smith; Shaibal Mukerjee; Casson Stallings; Eben D Thoma; Lillian Alston; Maribel Colon; Tai Wu; Stacy Henkle
Journal:  Atmos Environ (1994)       Date:  2017-08       Impact factor: 4.798

2.  Spatial analysis of volatile organic compounds using passive samplers in the Rubbertown industrial area of Louisville, Kentucky, USA.

Authors:  Shaibal Mukerjee; Luther A Smith; Eben D Thoma; Donald A Whitaker; Karen D Oliver; Rachelle Duvall; Tamira A Cousett
Journal:  Atmos Pollut Res       Date:  2020-06-01       Impact factor: 4.352

3.  Use of passive diffusion tubes to monitor air pollutants.

Authors:  David G Nash; David Leith
Journal:  J Air Waste Manag Assoc       Date:  2010-02       Impact factor: 2.235

4.  South Philadelphia passive sampler and sensor study.

Authors:  Eben D Thoma; Halley L Brantley; Karen D Oliver; Donald A Whitaker; Shaibal Mukerjee; Bill Mitchell; Tai Wu; Bill Squier; Elsy Escobar; Tamira A Cousett; Carol Ann Gross-Davis; Howard Schmidt; Dennis Sosna; Hallie Weiss
Journal:  J Air Waste Manag Assoc       Date:  2016       Impact factor: 2.235

5.  The spatial variation of O3, NO, NO2 and NO x and the relation between them in two Swedish cities.

Authors:  Annika Hagenbjörk; E Malmqvist; K Mattisson; Nilsson J Sommar; L Modig
Journal:  Environ Monit Assess       Date:  2017-03-13       Impact factor: 2.513

Review 6.  Analysis of benzene air quality standards, monitoring methods and concentrations in indoor and outdoor environment.

Authors:  Abinaya Sekar; George K Varghese; M K Ravi Varma
Journal:  Heliyon       Date:  2019-11-29

7.  Evaluation of land use regression models for nitrogen dioxide and benzene in Four US cities.

Authors:  Shaibal Mukerjee; Luther Smith; Lucas Neas; Gary Norris
Journal:  ScientificWorldJournal       Date:  2012-11-25

8.  Geospatial relationships of air pollution and acute asthma events across the Detroit-Windsor international border: study design and preliminary results.

Authors:  Lawrence D Lemke; Lois E Lamerato; Xiaohong Xu; Jason C Booza; John J Reiners; Delbert M Raymond Iii; Paul J Villeneuve; Eric Lavigne; Dana Larkin; Helene J Krouse
Journal:  J Expo Sci Environ Epidemiol       Date:  2013-11-13       Impact factor: 5.563

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.