Literature DB >> 19132353

A MIP-based flow-through fluoroimmunosensor as an alternative to immunosensors for the determination of digoxin in serum samples.

Gema Paniagua González1, Pilar Fernández Hernando, Jesús Senén Durand Alegría.   

Abstract

This work reports a comparative study of two automated flow-through fluorosensors for the determination of digoxin in serum samples: an immunosensor with an anti-digoxin polyclonal antibody as the reactive phase permanently immobilised on controlled-pore glass and a sensor with a selective reaction system based on a methacrylic molecularly imprinted polymer (MIP) synthesised by bulk polymerisation. The variables affecting the sensitivity and dynamic range of the sensors (e.g. the carrier and elution solutions, flow rates, pH and reagent concentrations) were optimized, and the binding characteristics of their reactive phases were compared in a competitive fluorescent assay. Digoxin was reproducibly determined by both sensors at the milligram per litre level (detection limit = 1.20 x 10(-3) mg L(-1) and RSD = 4-7% for the immunosensor; detection limit = 1.7 x 10(-5) mg L(-1) and RSD = 1-2% for the MIP sensor). No cross-reactivity with digoxin-related compounds was seen for either sensor at a digoxin/interferent ratio of 1:100. The lifetime of the immunosensor was about 50 immunoassays; its shelf life, when unused, is about 3 months. The lifetime of the MIP sensor was over 18 months. Both sensors were used to determine the digoxin concentration of human serum samples with satisfactory results.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19132353     DOI: 10.1007/s00216-008-2584-9

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  An electrochemical immunosensor for digoxin using core-shell gold coated magnetic nanoparticles as labels.

Authors:  Anita Ahmadi; Hanieh Shirazi; Narges Pourbagher; Abolfazl Akbarzadeh; Kobra Omidfar
Journal:  Mol Biol Rep       Date:  2014-01-07       Impact factor: 2.316

Review 2.  State-of-the-art of (bio)chemical sensor developments in analytical Spanish groups.

Authors:  María Reyes Plata; Ana María Contento; Angel Ríos
Journal:  Sensors (Basel)       Date:  2010-03-24       Impact factor: 3.576

3.  Smartphone-based molecularly imprinted sensors for rapid detection of thiamethoxam residues and applications.

Authors:  Sihua Peng; Aqiang Wang; Yuyang Lian; Xi Zhang; Bei Zeng; Qiulin Chen; Heming Yang; Jinlei Li; Limin Li; Jianguo Dan; Jianjun Liao; Shihao Zhou
Journal:  PLoS One       Date:  2021-11-08       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.