Lab-on-a-robot: integrated microchip CE, power supply, electrochemical detector, wireless unit, and mobile platform.

Christopher Berg1, David C Valdez, Phillip Bergeron, Maria F Mora, Carlos D Garcia, Arturo Ayon.   

Abstract

In this paper, the fabrication of a wireless mobile unit containing an electrochemical detection module and a 3-channel high-voltage power supply (HVPS) designed for microchip CE is described. The presented device consists of wireless global positioning system controlled robotics, an electrochemical detector utilizing signal conditioning analog circuitry and a digital feedback range controller, a HVPS, an air pump, and a CE microchip. A graphical user interface (LabVIEW) was also designed to communicate wirelessly with the device, from a distant personal computer communication port. The entire device is integrated and controlled by digital hardware implemented on a field programmable gate array development board. This lab-on-a-robot is able to navigate to a global position location, acquire an air sample, perform the analysis (injection, separation, and detection), and send the data (electropherogram) to a remote station without exposing the analyst to the testing environment.

Mesh:

Year:  2008        PMID: 19130571     DOI: 10.1002/elps.200800215

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  5 in total

1.  Research Spotlight: The next big thing is actually small.

Authors:  Carlos D Garcia
Journal:  Bioanalysis       Date:  2012-07       Impact factor: 2.681

2.  Evaluation of in-channel amperometric detection using a dual-channel microchip electrophoresis device and a two-electrode potentiostat for reverse polarity separations.

Authors:  Diogenes Meneses; Dulan B Gunasekara; Pann Pichetsurnthorn; José A F da Silva; Fabiane C de Abreu; Susan M Lunte
Journal:  Electrophoresis       Date:  2014-11-14       Impact factor: 3.535

3.  In-channel amperometric detection for microchip electrophoresis using a wireless isolated potentiostat.

Authors:  Dulan B Gunasekara; Matthew K Hulvey; Susan M Lunte
Journal:  Electrophoresis       Date:  2011-03-16       Impact factor: 3.535

Review 4.  Recent developments in instrumentation for capillary electrophoresis and microchip-capillary electrophoresis.

Authors:  Jessica L Felhofer; Lucas Blanes; Carlos D Garcia
Journal:  Electrophoresis       Date:  2010-08       Impact factor: 3.535

5.  Getting started with open-hardware: development and control of microfluidic devices.

Authors:  Eric Tavares da Costa; Maria F Mora; Peter A Willis; Claudimir L do Lago; Hong Jiao; Carlos D Garcia
Journal:  Electrophoresis       Date:  2014-07-14       Impact factor: 3.535