Literature DB >> 19127605

Effects of alignment on interface pressure for transtibial amputee during walking.

Xiaohong Jia1, Shuangfu Suo, Fan Meng, Rencheng Wang.   

Abstract

PURPOSE: To assess the mechanical behaviour at interface for unilateral transtibial amputees during walking when the prosthesis is misaligned, since studies examining interface pressure between residual limb and prosthetic socket have been restricted to unsupported stance and natural gait.
METHOD: One male subject with transtibial amputation volunteers for the study. Interface pressures over five sites are measured under three sagittal alignment settings. MP (mean peak interface pressure), TP(90+) (time in which pressure exceeded 90% of peak pressure) and TPI(90+) (time-pressure integral at the period of sustained sub-maximal load) are discussed for each alignment setting.
RESULTS: Compared with optimal alignment, the trend of interface pressure, the mean peak pressure do not change much,but the duration of sub-maximal pressure changes remarkably, except that at the patellar tendon, and finally the TPI(90+) changes considerably with different alignment settings.
CONCLUSIONS: The results offer the clinician and paramedical staff further insight in residual limb/socket interface mechanics in the transtibial amputation patients and provide potentially useful information for socket design and prosthesis fitting.

Entities:  

Mesh:

Year:  2008        PMID: 19127605     DOI: 10.1080/17483100802044634

Source DB:  PubMed          Journal:  Disabil Rehabil Assist Technol        ISSN: 1748-3107


  5 in total

1.  Radiographic parameters improve lower extremity prosthetic alignment.

Authors:  Ryan Mooney; Patrick Carry; Erin Wylie; Abby Schultz; Bryan McNair; Carol Page; Susan Biffl; Travis Heare
Journal:  J Child Orthop       Date:  2013-09-28       Impact factor: 1.548

2.  Amputee socks: thickness of multiple socks.

Authors:  John C Cagle; Alan J Yu; Marcia A Ciol; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2013-11-15       Impact factor: 1.895

Review 3.  Systematic Review of Studies Examining Transtibial Prosthetic Socket Pressures with Changes in Device Alignment.

Authors:  Philip Davenport; Siamak Noroozi; Philip Sewell; Saeed Zahedi
Journal:  J Med Biol Eng       Date:  2017-01-21       Impact factor: 1.553

Review 4.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

5.  Sensory neuroprosthesis improves postural stability during Sensory Organization Test in lower-limb amputees.

Authors:  Hamid Charkhkar; Breanne P Christie; Ronald J Triolo
Journal:  Sci Rep       Date:  2020-04-24       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.