Teodoro Espinosa-Solares1, Salvador Valle-Guadarrama, John Bombardiere, Max Domaschko, Michael Easter.
Abstract
The effect of heating strategy on power consumption and performance of a pilot plant anaerobic digester treating chicken litter, under thermophilic conditions, has been studied. Heating strategy was evaluated using three different spans (0.2 degrees C, 0.6 degrees C, and 1.0 degree C) for triggering the temperature control system from target temperature (56.7 degrees C). The hydraulic retention time in the pilot plant digester was in the range of 32 to 37 days, varying the total solids concentration fed from 5% to 6%. The results showed that under the experimental conditions, heating was the most energy-demanding process with 95.5% of the energy used. Increments up to 7.5% and 3.8%, respectively, on mechanical and heating power consumption, were observed as the span, for triggering the temperature control system from target temperature, was increased. Under the experimental conditions studied here, an increment of 30.6% on the global biodigester performance index was observed when a span of 1.0 degree C was compared to the one of 0.2 degrees C.Entities:
Mesh:
Year: 2009 PMID: 19127441 DOI: 10.1007/s12010-008-8487-6
Source DB: PubMed Journal: Appl Biochem Biotechnol ISSN: 0273-2289 Impact factor: 2.926