Literature DB >> 19123648

Pinhole shifting lifetime imaging microscopy.

Venkat K Ramshesh1, John J Lemasters.   

Abstract

Lifetime imaging microscopy is a powerful tool to probe biological phenomena independent of luminescence intensity and fluorophore concentration. We describe time-resolved imaging of long-lifetime luminescence with an unmodified commercial laser scanning confocal/multiphoton microscope. The principle of the measurement is displacement of the detection pinhole to collect delayed luminescence from a position lagging the rasting laser beam. As proof of principle, luminescence from microspheres containing europium (Eu(3+)), a red emitting probe, was compared to that of short-lifetime green-fluorescing microspheres and/or fluorescein and rhodamine in solution. Using 720-nm two-photon excitation and a pinhole diameter of 1 Airy unit, the short-lifetime fluorescence of fluorescein, rhodamine and green microspheres disappeared much more rapidly than the long-lifetime phosphorescence of Eu(3+) microspheres as the pinhole was repositioned in the lagging direction. In contrast, repositioning of the pinhole in the leading and orthogonal directions caused equal loss of short- and long-lifetime luminescence. From measurements at different lag pinhole positions, a lifetime of 270 micros was estimated for the Eu(3+) microspheres, consistent with independent measurements. This simple adaptation is the basis for quantitative 3-D lifetime imaging microscopy.

Entities:  

Mesh:

Year:  2008        PMID: 19123648      PMCID: PMC2743888          DOI: 10.1117/1.3027503

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  17 in total

1.  Fluorescence lifetime imaging by time-correlated single-photon counting.

Authors:  W Becker; A Bergmann; M A Hink; K König; K Benndorf; C Biskup
Journal:  Microsc Res Tech       Date:  2004-01-01       Impact factor: 2.769

2.  Quantitative imaging of protein-protein interactions by multiphoton fluorescence lifetime imaging microscopy using a streak camera.

Authors:  R V Krishnan; A Masuda; V E Centonze; B Herman
Journal:  J Biomed Opt       Date:  2003-07       Impact factor: 3.170

3.  Intracellular heterogeneity in mitochondrial membrane potentials revealed by a J-aggregate-forming lipophilic cation JC-1.

Authors:  S T Smiley; M Reers; C Mottola-Hartshorn; M Lin; A Chen; T W Smith; G D Steele; L B Chen
Journal:  Proc Natl Acad Sci U S A       Date:  1991-05-01       Impact factor: 11.205

Review 4.  Time-resolved fluorescence microscopy.

Authors:  Klaus Suhling; Paul M W French; David Phillips
Journal:  Photochem Photobiol Sci       Date:  2004-11-11       Impact factor: 3.982

Review 5.  Multiphoton fluorescence lifetime contrast in deep tissue imaging: prospects in redox imaging and disease diagnosis.

Authors:  V Krishnan Ramanujan; Jian-Hua Zhang; Eva Biener; Brian Herman
Journal:  J Biomed Opt       Date:  2005 Sep-Oct       Impact factor: 3.170

6.  Combination of a spinning disc confocal unit with frequency-domain fluorescence lifetime imaging microscopy.

Authors:  E B van Munster; J Goedhart; G J Kremers; E M M Manders; T W J Gadella
Journal:  Cytometry A       Date:  2007-04       Impact factor: 4.355

7.  Rapid frequency-domain FLIM spinning disk confocal microscope: lifetime resolution, image improvement and wavelet analysis.

Authors:  Chittanon Buranachai; Daichi Kamiyama; Akira Chiba; Benjamin D Williams; Robert M Clegg
Journal:  J Fluoresc       Date:  2008-03-07       Impact factor: 2.217

8.  A superfusion system to study border zones in confluent cultures of neonatal rat heart cells.

Authors:  C J Hyatt; J J Lemasters; B J Muller-Borer; T A Johnson; W E Cascio
Journal:  Am J Physiol       Date:  1998-06

9.  Error analysis of the rapid lifetime determination method for double-exponential decays and new windowing schemes.

Authors:  K K Sharman; A Periasamy; H Ashworth; J N Demas
Journal:  Anal Chem       Date:  1999-03-01       Impact factor: 6.986

10.  A continuously variable frequency cross-correlation phase fluorometer with picosecond resolution.

Authors:  E Gratton; M Limkeman
Journal:  Biophys J       Date:  1983-12       Impact factor: 4.033

View more
  4 in total

1.  Evaluating the performance of time-gated live-cell microscopy with lanthanide probes.

Authors:  Megha Rajendran; Lawrence W Miller
Journal:  Biophys J       Date:  2015-07-21       Impact factor: 4.033

2.  Time-resolved microscopy for imaging lanthanide luminescence in living cells.

Authors:  Nivriti Gahlaut; Lawrence W Miller
Journal:  Cytometry A       Date:  2010-09-07       Impact factor: 4.355

Review 3.  Lanthanide-based imaging of protein-protein interactions in live cells.

Authors:  Megha Rajendran; Engin Yapici; Lawrence W Miller
Journal:  Inorg Chem       Date:  2013-10-21       Impact factor: 5.165

4.  On-the-fly decoding luminescence lifetimes in the microsecond region for lanthanide-encoded suspension arrays.

Authors:  Yiqing Lu; Jie Lu; Jiangbo Zhao; Janet Cusido; Françisco M Raymo; Jingli Yuan; Sean Yang; Robert C Leif; Yujing Huo; James A Piper; J Paul Robinson; Ewa M Goldys; Dayong Jin
Journal:  Nat Commun       Date:  2014-05-06       Impact factor: 14.919

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.