Literature DB >> 19123647

Live imaging of blood flow in mammalian embryos using Doppler swept-source optical coherence tomography.

Irina V Larina1, Narendran Sudheendran, Mohamad Ghosn, James Jiang, Alex Cable, Kirill V Larin, Mary E Dickinson.   

Abstract

Studying hemodynamic changes during early mammalian embryonic development is critical for further advances in prevention, diagnostics, and treatment of congenital cardiovascular (CV) birth defects and diseases. Doppler optical coherence tomography (OCT) has been shown to provide sensitive measurements of blood flow in avian and amphibian embryos. We combined Doppler swept-source optical coherence tomography (DSS-OCT) and live mouse embryo culture to analyze blood flow dynamics in early embryos. SS-OCT structural imaging was used for the reconstruction of embryo morphology and the orientation of blood vessels, which is required for calculating flow velocity from the Doppler measurements. Spatially and temporally resolved blood flow profiles are presented for the dorsal aorta and a yolk sac vessel in a 9.5-day embryo. We demonstrate that DSS-OCT can be successfully used for structural analysis and spatially and temporally resolved hemodynamic measurements in developing early mammalian embryos.

Entities:  

Mesh:

Year:  2008        PMID: 19123647     DOI: 10.1117/1.3046716

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  46 in total

1.  Rotational imaging optical coherence tomography for full-body mouse embryonic imaging.

Authors:  Chen Wu; Narendran Sudheendran; Manmohan Singh; Irina V Larina; Mary E Dickinson; Kirill V Larin
Journal:  J Biomed Opt       Date:  2016-02       Impact factor: 3.170

2.  Increased regurgitant flow causes endocardial cushion defects in an avian embryonic model of congenital heart disease.

Authors:  Stephanie M Ford; Matthew T McPheeters; Yves T Wang; Pei Ma; Shi Gu; James Strainic; Christopher Snyder; Andrew M Rollins; Michiko Watanabe; Michael W Jenkins
Journal:  Congenit Heart Dis       Date:  2017-02-17       Impact factor: 2.007

3.  Multiple-cardiac-cycle noise reduction in dynamic optical coherence tomography of the embryonic heart and vasculature.

Authors:  Sandeep Bhat; Irina V Larina; Kirill V Larin; Mary E Dickinson; Michael Liebling
Journal:  Opt Lett       Date:  2009-12-01       Impact factor: 3.776

4.  Live imaging of rat embryos with Doppler swept-source optical coherence tomography.

Authors:  Irina V Larina; Kenryo Furushima; Mary E Dickinson; Richard R Behringer; Kirill V Larin
Journal:  J Biomed Opt       Date:  2009 Sep-Oct       Impact factor: 3.170

5.  Optical coherence tomography for high-resolution imaging of mouse development in utero.

Authors:  Saba H Syed; Kirill V Larin; Mary E Dickinson; Irina V Larina
Journal:  J Biomed Opt       Date:  2011-04       Impact factor: 3.170

6.  Optical coherence tomography guided microinjections in live mouse embryos: high-resolution targeted manipulation for mouse embryonic research.

Authors:  Saba H Syed; Andrew J Coughlin; Monica D Garcia; Shang Wang; Jennifer L West; Kirill V Larin; Irina V Larina
Journal:  J Biomed Opt       Date:  2015-05       Impact factor: 3.170

7.  Live four-dimensional optical coherence tomography reveals embryonic cardiac phenotype in mouse mutant.

Authors:  Andrew L Lopez; Shang Wang; Kirill V Larin; Paul A Overbeek; Irina V Larina
Journal:  J Biomed Opt       Date:  2015       Impact factor: 3.170

8.  Comparative assessments of the effects of alcohol exposure on fetal brain development using optical coherence tomography and ultrasound imaging.

Authors:  Narendran Sudheendran; Shameena Bake; Rajesh C Miranda; Kirill V Larin
Journal:  J Biomed Opt       Date:  2013-02       Impact factor: 3.170

9.  Optical coherence tomography for live phenotypic analysis of embryonic ocular structures in mouse models.

Authors:  Irina V Larina; Saba H Syed; Narendran Sudheendran; Paul A Overbeek; Mary E Dickinson; Kirill V Larin
Journal:  J Biomed Opt       Date:  2012-08       Impact factor: 3.170

10.  4D reconstruction of the beating embryonic heart from two orthogonal sets of parallel optical coherence tomography slice-sequences.

Authors:  Sandeep Bhat; Irina V Larina; Kirill V Larin; Mary E Dickinson; Michael Liebling
Journal:  IEEE Trans Med Imaging       Date:  2012-12-04       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.