We have developed a compact, isolated, physiological, constant-current stimulator that is powered and controlled by a universal serial bus (USB) interface. The stimulator is designed to be used in ex vivo cardiac experiments but is suitable for a wide variety of settings. The cost and features compare very favorably with commercial stimulators usually used in research and student laboratories. In addition to being USB powered, other novel aspects of our stimulator include the ability to produce large currents, up to 100 mA through a typical 1 kOmega load, by means of a single high-voltage dc-to-dc converter; user-specified variable period, magnitude, and duration of complex monophasic or biphasic sequences; and easy integration via hardware or software into existing experimental setups.

Mesh:

Year:  2008        PMID: 19123594      PMCID: PMC2736648          DOI: 10.1063/1.3030861

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  5 in total

1.  An optically coupled power stimulus isolation unit with high voltage and fast rise time output.

Authors:  R O Brasil; J H Leal-Cardoso
Journal:  Braz J Med Biol Res       Date:  1999-06       Impact factor: 2.590

2.  High-resolution high-speed panoramic cardiac imaging system.

Authors:  Dale W Evertson; Mark R Holcomb; Matthew C Eames; Mark-Anthony Bray; Veniamin Y Sidorov; Junkai Xu; Holley Wingard; Hana M Dobrovolny; Marcella C Woods; Daniel J Gauthier; John P Wikswo
Journal:  IEEE Trans Biomed Eng       Date:  2008-03       Impact factor: 4.538

3.  A versatile microprocessor-based multichannel stimulator for skeletal muscle cardiac assist.

Authors:  E A Cheever; D R Thompson; B L Cmolik; W P Santamore; D T George
Journal:  IEEE Trans Biomed Eng       Date:  1998-01       Impact factor: 4.538

4.  Effects of unipolar stimulation on voltage and calcium distributions in the isolated rabbit heart.

Authors:  Veniamin Y Sidorov; Mark R Holcomb; Marcella C Woods; Richard A Gray; John P Wikswo
Journal:  Basic Res Cardiol       Date:  2008-07-19       Impact factor: 17.165

5.  Tools for physiology labs: inexpensive equipment for physiological stimulation.

Authors:  Bruce R Land; Bruce R Johnson; Robert A Wyttenbach; Ronald R Hoy
Journal:  J Undergrad Neurosci Educ       Date:  2004-10-15
  5 in total
  2 in total

1.  Continuous-waveform constant-current isolated physiological stimulator.

Authors:  Mark R Holcomb; Jack M Devine; Rene Harder; Veniamin Y Sidorov
Journal:  Rev Sci Instrum       Date:  2012-04       Impact factor: 1.523

2.  The potential of dual camera systems for multimodal imaging of cardiac electrophysiology and metabolism.

Authors:  Mark R Holcomb; Marcella C Woods; Ilija Uzelac; John P Wikswo; Jonathan M Gilligan; Veniamin Y Sidorov
Journal:  Exp Biol Med (Maywood)       Date:  2009-08-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.