Use of multichannel electrogastrography for noninvasive assessment of gastric myoelectrical activity in dogs.

Judith B Koenig1, Christina E W Martin, Howard Dobson, Martin P Mintchev.   

Abstract

OBJECTIVE: To evaluate whether changes in gastric myoelectrical activity in healthy, awake dogs can be detected via multichannel electrogastrography (EGG). ANIMALS: 6 healthy hound-breed dogs. PROCEDURES: For each dog, 8-channel EGG was performed after food had been withheld for 12 hours and at 30 minutes after subsequent feeding; 60 minutes after feeding, atropine (0.04 mg/kg) was administered IM to induce ileus, and 30 minutes later, EGG was again performed. Mean cycles per minute (cpm) values of the dominant frequency (a measure of the rhythmicity of gastric electrical activity) and mean power ratios (ie, power measured after treatment divided by the power measured when food was withheld) were calculated. Motility of the gastric antrum was assessed via B-mode ultrasonography during the same phases; contractions determined ultrasonographically were correlated with EGG power for each channel in each phase.
RESULTS: The criterion for stability (SD of the dominant frequency < 15% of the cpm value in at least 3 of the 8 EGG channels) was met in 4 of the 6 dogs (only in long-distance channels). The mean power ratios were significantly higher in the postprandial phase than in the ileus phase. Compared with the postprandial phase, significantly fewer contractions per minute were evident ultrasonographically in the ileus and food-withholding phases. There was a significant and good correlation between EGG power and ultrasonographic findings in all 8 channels. CONCLUSIONS AND CLINICAL RELEVANCE: Electrogastrography may be useful in assessing gastric myoelectrical activities in awake dogs with naturally occurring gastrointestinal disease, including gastric dilatation-volvulus.

Entities:  

Mesh:

Year:  2009        PMID: 19119943     DOI: 10.2460/ajvr.70.1.11

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  1 in total

1.  In vivo experimental validation of detection of gastric slow waves using a flexible multichannel electrogastrography sensor linear array.

Authors:  Atchariya Sukasem; Stefan Calder; Timothy R Angeli-Gordon; Christopher N Andrews; Gregory O'Grady; Armen Gharibans; Peng Du
Journal:  Biomed Eng Online       Date:  2022-06-27       Impact factor: 3.903

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.