Literature DB >> 19119546

Effect of digital noise filters on diagnostic radiographs for the diagnosis of experimental root fractures.

D Brüllmann1, V Witzel, B Willershausen, B d'Hoedt.   

Abstract

This article discusses basic concepts of noise suppression for digital radiographs, and shows how false application of algorithms available can lead to a loss of information. Noise suppression realized with low pass convolution filters are designed to decrease strong grey level changes of neighboring pixels. Sixty-two extracted fully intact premolars were selected and treated usingthe crown-down technique to prepare them for experimental fractures. A total of 358 radiographs were taken, of which 312 images were selected with clearly visible root fractures. The selected radiographs were stored as uncompressed images and manipulated with 8 different convolution filters. A total of 2496 raw and filtered images were inspected for visible root fractures. Only the arithmetic mean filter with 5 x 5 kernel size led to a deletion of the visible fracture line in 33.3% of the inspected cases. The other filters proved to be useful for noise reduction without loss of any necessary diagnostic information. None of the filters improved the diagnostic outcome in the 46 remaining radiographs which did not show clearly visible root fractures before application of the filters.

Entities:  

Mesh:

Year:  2008        PMID: 19119546

Source DB:  PubMed          Journal:  Int J Comput Dent        ISSN: 1463-4201            Impact factor:   1.883


  4 in total

1.  Influence of cone beam CT enhancement filters on diagnosis ability of longitudinal root fractures.

Authors:  M C C Nascimento; Y Nejaim; S M de Almeida; F N Bóscolo; F Haiter-Neto; L C Sobrinho; E J N L Silva
Journal:  Dentomaxillofac Radiol       Date:  2014-01-22       Impact factor: 2.419

2.  Effects of five levels of noise reduction applied to indirect digital radiography on diagnostic accuracy of external apical root resorption.

Authors:  Sanaz Sharifi Shoshtari; Seyed Arman Mohagheghi; Nastaran Farhadi; Negin Kheradmand; Lida Naderi
Journal:  Dent Res J (Isfahan)       Date:  2020-03-17

3.  Effect of Filtration and Slice Thickness of Cone-Beam Computed Tomography Images on Occlusal Caries Detection: An Ex Vivo Study.

Authors:  Mehrdad Abdinian; Marzieh Ghaiour
Journal:  J Dent (Tehran)       Date:  2018-09

4.  Effect of digital noise reduction on the accuracy of endodontic file length determination.

Authors:  Mojdeh Mehdizadeh; Abbas Ali Khademi; Ali Shokraneh; Nastaran Farhadi
Journal:  Imaging Sci Dent       Date:  2013-09-23