Literature DB >> 19117927

Poly-epsilon-caprolactone intravitreous devices: an in vivo study.

Armando Silva-Cunha1, Silvia Ligorio Fialho, Marie-Christine Naud, Francine Behar-Cohen.   

Abstract

PURPOSE: The objective of this study was to evaluate the long-term safety and pharmacokinetic profile of a dexamethasone-loaded poly-epsilon-caprolactone (PCL) intravitreous implant.
METHODS: The PCL devices were prepared by compression and were inserted into the vitreous of pigmented rabbits. At different time points, vitreous samples were retrieved, and dexamethasone concentration was analyzed by high-performance liquid chromatography. The biodegradation of the implants was evaluated by scanning electron microscopy, and the dexamethasone remaining was evaluated at the end of follow-up. Clinical and histologic examinations were performed to evaluate the implant's tolerance.
RESULTS: The PCL implant allows for a controlled and prolonged delivery of dexamethasone in rabbits eyes since it released the drug within the therapeutic range for at least 55 weeks. At 55 weeks approximately 79% of the drug was still present in the implant. Biodegradation study showed that PCL implants degradation is very slow. Clinical and histologic observations showed that the devices were very well tolerated in the rabbit eye.
CONCLUSIONS: This study demonstrates the feasibility and tolerance of intravitreous PCL drug delivery systems, which can offer a wide range of applications for intraocular drug delivery because of their controlled and prolonged release over months or even years.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19117927     DOI: 10.1167/iovs.08-2969

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  12 in total

Review 1.  Long acting systemic HIV pre-exposure prophylaxis: an examination of the field.

Authors:  William R Lykins; Ellen Luecke; Daniel Johengen; Ariane van der Straten; Tejal A Desai
Journal:  Drug Deliv Transl Res       Date:  2017-12       Impact factor: 4.617

2.  Polymeric endoaortic paving: Mechanical, thermoforming, and degradation properties of polycaprolactone/polyurethane blends for cardiovascular applications.

Authors:  J H Ashton; J A M Mertz; J L Harper; M J Slepian; J L Mills; D V McGrath; J P Vande Geest
Journal:  Acta Biomater       Date:  2010-09-09       Impact factor: 8.947

3.  In vivo and in vitro sustained release of ranibizumab from a nanoporous thin-film device.

Authors:  Kevin D Lance; Daniel A Bernards; Natalie A Ciaccio; Samuel D Good; Thaís S Mendes; Max Kudisch; Elliot Chan; Mynna Ishikiriyama; Robert B Bhisitkul; Tejal A Desai
Journal:  Drug Deliv Transl Res       Date:  2016-12       Impact factor: 4.617

4.  Intravitreal controlled release of dexamethasone from engineered microparticles of porous silicon dioxide.

Authors:  Chengyun Wang; Huiyuan Hou; Kaihui Nan; Michael J Sailor; William R Freeman; Lingyun Cheng
Journal:  Exp Eye Res       Date:  2014-11-05       Impact factor: 3.467

5.  Ocular biocompatibility and structural integrity of micro- and nanostructured poly(caprolactone) films.

Authors:  Daniel A Bernards; Robert B Bhisitkul; Paula Wynn; Mark R Steedman; On-Tat Lee; Fergus Wong; Somanus Thoongsuwan; Tejal A Desai
Journal:  J Ocul Pharmacol Ther       Date:  2013-02-07       Impact factor: 2.671

6.  In Vitro and In Vivo Sustained Zero-Order Delivery of Rapamycin (Sirolimus) From a Biodegradable Intraocular Device.

Authors:  Kevin D Lance; Samuel D Good; Thaís S Mendes; Mynna Ishikiriyama; Patrick Chew; Laurel S Estes; Kazuhito Yamada; Sri Mudumba; Robert B Bhisitkul; Tejal A Desai
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-11       Impact factor: 4.799

7.  Subretinal implantation of electrospun, short nanowire, and smooth poly(ε-caprolactone) scaffolds to the subretinal space of porcine eyes.

Authors:  A T Christiansen; S L Tao; M Smith; G E Wnek; J U Prause; M J Young; H Klassen; H J Kaplan; M la Cour; J F Kiilgaard
Journal:  Stem Cells Int       Date:  2012-03-15       Impact factor: 5.443

Review 8.  Polymeric Implants for the Treatment of Intraocular Eye Diseases: Trends in Biodegradable and Non-Biodegradable Materials.

Authors:  Paulina García-Estrada; Miguel A García-Bon; Edgar J López-Naranjo; Dulce N Basaldúa-Pérez; Arturo Santos; Jose Navarro-Partida
Journal:  Pharmaceutics       Date:  2021-05-12       Impact factor: 6.321

Review 9.  Intravitreal devices for the treatment of vitreous inflammation.

Authors:  John B Christoforidis; Susie Chang; Angela Jiang; Jillian Wang; Colleen M Cebulla
Journal:  Mediators Inflamm       Date:  2012-09-05       Impact factor: 4.711

10.  Application of 5-Fluorouracil-Polycaprolactone Sustained-Release Film in Ahmed Glaucoma Valve Implantation Inhibits Postoperative Bleb Scarring in Rabbit Eyes.

Authors:  Xiu-Zeng Bi; Wei-Hua Pan; Xin-Ping Yu; Zong-Ming Song; Zeng-Jin Ren; Min Sun; Cong-Hui Li; Kai-Hui Nan
Journal:  PLoS One       Date:  2015-11-18       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.