Literature DB >> 19117391

Amperometric oxygen sensor based on a platinum nanoparticle-modified polycrystalline boron doped diamond disk electrode.

Laura Hutton1, Mark E Newton, Patrick R Unwin, Julie V Macpherson.   

Abstract

Pt nanoparticle (NP)-modified polycrystalline boron-doped diamond (pBDD) disk electrodes have been fabricated and employed as amperometric sensors for the determination of dissolved oxygen concentration in aqueous solution. pBDD columns were cut using laser micromachining techniques and sealed in glass, in order to make disk electrodes which were then characterized electrochemically. Electrodeposition of Pt onto the diamond electrodes was optimized so as to give the maximum oxygen reduction peak current with the lowest background signal. Pt NPs, >0-10 nm diameter, were found to deposit randomly across the pBDD electrode, with no preference for grain boundaries. The more conductive grains were found to promote the formation of smaller nanoparticles at higher density. With the use of potential step chronoamperometry, in which the potential was stepped to a diffusion-limited value, a four electron oxygen reduction process was found to occur at the Pt NP-modified pBDD electrode. Furthermore the chronoamperometric response scaled linearly with dissolved oxygen concentration, varied by changing the oxygen/nitrogen ratio of gas flowed into solution. The sensor was used to detect dissolved oxygen concentrations with high precision over the pH range 4-10.

Entities:  

Year:  2009        PMID: 19117391     DOI: 10.1021/ac8020906

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

Review 1.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2010-06-15       Impact factor: 6.986

2.  In vitro Detection of Hypoxia using a Ratiometric Quantum Dot-based Oxygen Sensor.

Authors:  Armen Shamirian; Hamid Samareh Afsari; Asra Hassan; Lawrence W Miller; Preston T Snee
Journal:  ACS Sens       Date:  2016-09-20       Impact factor: 7.711

3.  Reversible oxygen gas sensor based on electrochemiluminescence.

Authors:  Lihua Zhang; Francis Tsow; Erica Forzani; Nongjian Tao
Journal:  Chem Commun (Camb)       Date:  2010-05-21       Impact factor: 6.222

4.  The Importance of Cannizzaro-Type Reactions during Electrocatalytic Reduction of Carbon Dioxide.

Authors:  Yuvraj Y Birdja; Marc T M Koper
Journal:  J Am Chem Soc       Date:  2017-01-30       Impact factor: 15.419

5.  Performance modulation through selective, homogenous surface doping of lanthanum strontium ferrite electrodes revealed by in situ PLD impedance measurements.

Authors:  Christoph Riedl; Matthäus Siebenhofer; Andreas Nenning; Gernot Friedbacher; Maximilian Weiss; Christoph Rameshan; Johannes Bernardi; Andreas Limbeck; Markus Kubicek; Alexander Karl Opitz; Juergen Fleig
Journal:  J Mater Chem A Mater       Date:  2021-12-03

6.  Versatile DIY Route for Incorporation of a Wide Range of Electrode Materials into Rotating Ring Disk Electrodes.

Authors:  Joshua J Tully; Zhaoyan Zhang; Irina M Terrero Rodríguez; Lee Butcher; Julie V Macpherson
Journal:  Anal Chem       Date:  2022-06-29       Impact factor: 8.008

Review 7.  New trends in the electrochemical sensing of dopamine.

Authors:  Krystyna Jackowska; Pawel Krysinski
Journal:  Anal Bioanal Chem       Date:  2012-12-16       Impact factor: 4.142

8.  Surface Modification of Boron-Doped Diamond with Microcrystalline Copper Phthalocyanine: Oxygen Reduction Catalysis.

Authors:  Patrick Gan; John S Foord; Richard G Compton
Journal:  ChemistryOpen       Date:  2015-05-20       Impact factor: 2.911

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.