Literature DB >> 19113073

Comparison of methods used to correct a lingually tilted mandibular molar: 3-D analysis using the finite element method (FEM).

Allahyar Geramy1, Hannaneh Ghadirian.   

Abstract

BACKGROUND: Methods used to upright lingually tilted mandibular molars frequently result in extrusion and unwanted rotations. AIM: To use the finite element method (FEM) to compare three springs designed to upright a lingually tilted mandibular first molar.
METHODS: A 3-D computer model of a lingually tilted mandibular first molar was designed. The FEM was used to compare movement of the molar during uprighting with either a single horizontal helix, an open vertical loop, or a new spring with two vertical helices wound around and perpendicular to the long axis of the archwire. Each spring was assumed to be part of a continuous 0.016 x 0.022 inch stainless steel archwire, and each spring was placed mesial to the buccal tube on the first molar.
RESULTS: From the mesial perspective, all designs moved the crown of the lingually tilted molar buccally and the root apex lingually. From the occlusal perspective: the horizontal helix uprighted the molar with a disto-buccal rotation; the open vertical loop uprighted the molar with a mesio-buccal rotation; and the new design uprighted the lingually tilted molar around a mesio-distal axis.
CONCLUSION: Using FEM, the most suitable design was a double helix formed around and perpendicular to the long axis of the archwire and sited mesial to the tilted molar. It was the only spring to upright the lingually tilted molar without an unwanted rotation.

Entities:  

Mesh:

Year:  2008        PMID: 19113073

Source DB:  PubMed          Journal:  Aust Orthod J        ISSN: 0587-3908


  6 in total

1.  Three-Dimensional Control on Lingually Rolled in Molars using a 3D Lingual Arch.

Authors:  Sunil Sunny; Denny P Joseph; Neethu Mathew; Roshini Sara Rajan; Eldo Kurian
Journal:  J Clin Diagn Res       Date:  2017-08-01

2.  Effect of Extension and Type of Composite-Restored Class II Cavities on Biomechanical Properties of Teeth: A Three Dimensional Finite Element Analysis.

Authors:  Azam Valian; Elham Moravej-Salehi; Allahyar Geramy; Elham Faramarzi
Journal:  J Dent (Tehran)       Date:  2015-02

3.  Unilateral Outer Bow Expanded Cervical Headgear Force System: 3D Analysis Using Finite Element Method.

Authors:  Allahyar Geramy; Omid Mortezai; Masomeh Esmaily; Hojat Darvishpour
Journal:  J Dent (Tehran)       Date:  2015-04

4.  Effect of the number of implants on stress distribution of anterior implant-supported fixed prostheses combined with a removable partial denture: a finite element analysis.

Authors:  Minoo Mahshid; Allahyar Geramy; Massoud Ejlali; Majid Sedaghat Monfared; Shirin Rezvani Habib Abadi
Journal:  J Dent (Tehran)       Date:  2014-05-31

5.  Anterior Teeth Splinting After Orthodontic Treatment: 3D Analysis Using Finite Element Method.

Authors:  A Geramy; J M Retrouvey; F Sobuti; H Salehi
Journal:  J Dent (Tehran)       Date:  2012-06-30

6.  A CBCT evaluation of molar uprighting by conventional versus microimplant-assisted methods: an in-vivo study.

Authors:  Sergio Martires; Nandini V Kamat; Sapna Raut Dessai
Journal:  Dental Press J Orthod       Date:  2018 May-Jun
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.