Literature DB >> 19112782

Novel drug eluting stent system for customised treatment of coronary lesions: CUSTOM I feasibility trial 24 month results.

Eberhard Grube1, Horst Sievert, Karl-Eugen Hauptmann, Ralf Mueller, Ulrich Gerckens, Lutz Buellesfeld, Junya Ako, Takao Shimohama, Marco Costa, Peter Fitzgerald.   

Abstract

AIMS: The Custom NX 36 Drug Eluting Stent (DES) System is designed to treat coronary lesions via in situ stent length customisation. The stent evaluated in this study consists of nine interdigitated stent segments, each 4 mm in length, coated with a biodegradable formulation of Biolimus A9 and Poly-Lactic-Acid, a biodegradable drug carrier, and loaded into a unique sheath protected, integrated balloon delivery system. METHODS AND
RESULTS: The objective of this non-randomised prospective multicentre CUSTOM I Trial was to demonstrate the safety of in situ stent length customisation in 30 consecutive patients. Angiographic (QCA) and intravascular ultrasound (IVUS) follow-up was performed at two cohort time intervals: four (n=10) or eight (n=20) months. Mean lesion length and reference vessel diameters were 17.7 +/- 9.6 mm and 2.6 +/- 0.3 mm, respectively. Procedural success was 93%. There were three MACEs in the study population from enrollment through to twenty-four month follow-up. The in-hospital MACE rate was 2/30, with non-Q-wave myocardial infarctions events in two patients who recovered without further sequelae. At five months, one patient who had crossed over initially to PTCA required CABG surgery. Results from QCA and IVUS assessments at four and eight months showed no binary restenosis, mean in-stent late luminal loss of 0.25 +/- 0.23 mm and 0.26 +/- 0.23 mm.
CONCLUSIONS: This first evaluation of the new customisable Biolimus A9-eluting Custom NX stent suggests safety and efficacy through twenty-four month follow-up. Further evaluations are warranted to confirm the overall favourable outcomes.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19112782     DOI: 10.4244/eijv4i1a13

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  2 in total

1.  The pharmacokinetics of Biolimus A9 after elution from the BioMatrix II stent in patients with coronary artery disease: the Stealth PK Study.

Authors:  Miodrag C Ostojic; Zoran Perisic; Dragan Sagic; Robert Jung; Yan-Ling Zhang; Jamie Bendrick-Peart; Ronald Betts; Uwe Christians
Journal:  Eur J Clin Pharmacol       Date:  2010-10-09       Impact factor: 2.953

Review 2.  Intravascular ultrasound: principles and cerebrovascular applications.

Authors:  H Zacharatos; A E Hassan; A I Qureshi
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-04       Impact factor: 3.825

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.