Literature DB >> 19110809

Early echocardiographic evaluation following percutaneous implantation with the self-expanding CoreValve Revalving System aortic valve bioprosthesis.

Peter P Th De Jaegere1, Nicolo Piazza, Tjebbe W Galema, Amber Otten, Osama I Soliman, Bas M Van Dalen, Marcel L Geleijnse, Arie-Pieter Kappetein, Hector M Garcia Garcia, Gerrit-Anne Van Es, Patrick W Serruys.   

Abstract

AIMS: Although safety and feasibility studies have been published, there are few reports dedicated to the echocardiographic evaluation of patients following percutaneous aortic valve replacement (PAVR). This report describes the early echocardiographic evaluation of patients undergoing PAVR with the CoreValve Revalving System. METHODS AND
RESULTS: The population consisted of 33 consecutive patients with aortic stenosis who underwent successful PAVR. Echocardiograms were performed pre-treatment (123+/-110 days prior), post-treatment (6+/-2 days) and post-discharge (80+/-64 days). Aortic valve function and left ventricular dimensions, systolic and diastolic function were assessed pre- and post-implantation. The mean age was 81+/-7 years and the mean Logistic Euroscore was 20+/-12. Following PAVR, the mean transaortic valve gradient decreased (46+/-16 mmHg pre-treatment vs. 12+/-7 mmHg post-treatment vs. 9+/-5 mmHg post-discharge, p<0.001) and the mean effective orifice area increased (0.75+/-0.23 cm2 pre-treatment vs. 1.97+/-0.85 cm2 post-treatment vs. 1.72+/-0.45 cm2 post-discharge, p<0.001). There was no significant change in mean ejection fraction (41+/-12% pre-treatment vs. 46+/-15% post-treatment vs. 44+/-13% post-discharge, p=0.44). Approximately two-thirds of patients had no change in diastolic function at follow-up.
CONCLUSION: Following implantation, there was a sustained decrease in aortic valve gradient and increase in aortic valve area. In addition, the mean ejection fraction did not change significantly and in the majority of patients, diastolic function was unchanged.

Entities:  

Mesh:

Year:  2008        PMID: 19110809     DOI: 10.4244/eijv4i3a63

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  7 in total

1.  Preserved prognostic value of preinterventional troponin T levels despite successful TAVI in patients with severe aortic stenosis.

Authors:  Emmanuel Chorianopoulos; Ulrike Krumsdorf; Nicolas Geis; Sven T Pleger; Evangelos Giannitsis; Hugo A Katus; Raffi Bekeredjian
Journal:  Clin Res Cardiol       Date:  2013-10-06       Impact factor: 5.460

2.  Association of individual aortic leaflet calcification on paravalvular regurgitation and conduction abnormalities with self-expanding trans-catheter aortic valve insertion.

Authors:  Ciara Mahon; Allan Davies; Alessia Gambaro; Francesca Musella; Ana Luisa Costa; Vasileios Panoulas; Edward Nicol; Alison Duncan; Simon Davies; Saeed Mirsadraee
Journal:  Quant Imaging Med Surg       Date:  2021-05

3.  The next revolution: percutaneous aortic valve replacement.

Authors:  Martin B Leon; Eugenia Nikolsky
Journal:  Rambam Maimonides Med J       Date:  2010-10-31

4.  Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium.

Authors:  Martin B Leon; Nicolo Piazza; Eugenia Nikolsky; Eugene H Blackstone; Donald E Cutlip; Arie Pieter Kappetein; Mitchell W Krucoff; Michael Mack; Roxana Mehran; Craig Miller; Marie-Angèle Morel; John Petersen; Jeffrey J Popma; Johanna J M Takkenberg; Alec Vahanian; Gerrit-Anne van Es; Pascal Vranckx; John G Webb; Stephan Windecker; Patrick W Serruys
Journal:  Eur Heart J       Date:  2011-01-06       Impact factor: 29.983

5.  The impact of transcatheter aortic valve implantation on left ventricular performance and wall thickness - single-centre experience.

Authors:  Patrycjusz Stokłosa; Piotr Szymański; Maciej Dąbrowski; Dariusz Zakrzewski; Piotr Michałek; Ewa Orłowska-Baranowska; Kamal El-Hassan; Zbigniew Chmielak; Adam Witkowski; Tomasz Hryniewiecki
Journal:  Postepy Kardiol Interwencyjnej       Date:  2015-03-06       Impact factor: 1.426

6.  Clinical utility of a predictive model for paravalvular aortic regurgitation after transcatheter aortic valve implantation with a self-expandable prosthesis.

Authors:  Ahmad E Mostafa; Gert Richardt; Mohamed Abdel-Wahab
Journal:  Egypt Heart J       Date:  2017-07-20

7.  Transcatheter Aortic Valve Replacement: The Experience of One Brazilian Health Care Center.

Authors:  Fabiula Schwartz Azevedo; Marcelo Goulart Correa; Débora Holanda Gonçalves Paula; Alex Dos Santos Felix; Luciano Herman Juaçaba Belém; Ana Paula Chedid Mendes; Valeria Gonçalves Silva; Bruno Miranda Marques; Andrey José de Oliveira Monteiro; Clara Weksler; Alexandre Siciliano Colafranceschi; Daniel Arthur Barata Kasal
Journal:  Braz J Cardiovasc Surg       Date:  2018 Jan-Feb
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.