Literature DB >> 19110789

Titanium-nitride-oxide coated stents versus paclitaxel-eluting stents in acute myocardial infarction: a 12-months follow-up report from the TITAX AMI trial.

Pasi P Karjalainen1, Antti Ylitalo, Matti Niemelä, Kari Kervinen, Timo Mäkikallio, Mikko Pietili, Jussi Sia, Petri Tuomainen, Kai Nyman, K E Juhani Airaksinen.   

Abstract

AIMS: The aim of this study was to evaluate the effectiveness of titanium-nitride-oxide (TITANOX)-coated stent and paclitaxel-eluting stent (PES) in patients presenting with acute myocardial infarction (MI). METHODS AND
RESULTS: A total of 425 patients presenting with acute non-ST-elevation MI or ST-elevation MI were randomly assigned to receive TITANOX-coated stent or PES. The primary end point was a composite of MI, target lesion revascularisation (TLR) or death from cardiac causes. At 12 months, there was no significant difference between patients receiving TITANOX-coated stent or PES in the rates of primary end point (10.3% vs. 12.8%, P=0.5), MI (4.2% vs. 8.1%, P=0.1), or TLR (9.3% vs. 7.1%, P=0.5), respectively. The incidence of stent thrombosis, defined according to Academic Research Consortium classification, was significantly lower in the TITANOX group compared to the PES group (0.9% vs. 4.3%, P=0.03).
CONCLUSIONS: TITANOX-coated stent and PES resulted in comparable clinical outcomes during 12 months follow-up among patients treated for acute MI.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19110789     DOI: 10.4244/eijv4i2a42

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  6 in total

Review 1.  New drug-eluting stent concepts.

Authors:  Rainer Wessely
Journal:  Nat Rev Cardiol       Date:  2010-03-02       Impact factor: 32.419

2.  Stent strut coverage of titanium-nitride-oxide coated stent compared to paclitaxel-eluting stent in acute myocardial infarction: TITAX-OCT study.

Authors:  Tuomas Lehtinen; K E Juhani Airaksinen; Antti Ylitalo; Pasi P Karjalainen
Journal:  Int J Cardiovasc Imaging       Date:  2012-02-24       Impact factor: 2.357

3.  Titanium-nitride-oxIde-coated stents multicenter registry in diaBEtic patienTs: the TIBET registry.

Authors:  Mariano Valdés Chavarri; Mariano Valdés Chavarri; Armando Bethencourt; Eduardo Pinar; Alfredo Gomez; Javier Fernández Portales; Francisco Pomar; Isabel Calvo; Jose Ramón López-Minguez; Jose Ramón López Minguez; Raúl Valdesuso; José Moreu; Antonio Martínez; Wail Nammas
Journal:  Heart Vessels       Date:  2011-03-30       Impact factor: 2.037

4.  Drug-eluting stents in acute myocardial infarction: updated meta-analysis of randomized trials.

Authors:  Alban Dibra; Klaus Tiroch; Stefanie Schulz; Henning Kelbaek; Christian Spaulding; Gerrit J Laarman; Marco Valgimigli; Emilio Di Lorenzo; Christoph Kaiser; Ilkka Tierala; Julinda Mehilli; Gianluca Campo; Leif Thuesen; Maarten A Vink; Martin J Schalij; Roberto Violini; Albert Schömig; Adnan Kastrati
Journal:  Clin Res Cardiol       Date:  2010-03-11       Impact factor: 5.460

5.  Short and long-term benefits of sirolimus-eluting stent in ST-segment elevation myocardial infarction: a meta-analysis of randomized trials.

Authors:  Giuseppe De Luca; Marco Valgimigli; Christian Spaulding; Maurizio Menichelli; Hans Peter Brunner-La Rocca; Bas L van der Hoeven; Emilio Di Lorenzo; Luis-S Diaz de la Llera; Vincenzo Pasceri; Undine Pittl; Gianfranco Percoco; Roberto Violini; Gregg W Stone
Journal:  J Thromb Thrombolysis       Date:  2009-02-04       Impact factor: 2.300