Literature DB >> 19110128

Investigation into classification/sourcing of suspect counterfeit Heptodintrade mark tablets by near infrared chemical imaging.

Marta B Lopes1, Jean-Claude Wolff.   

Abstract

Near infrared chemical imaging (NIR-CI) analysis was performed on 55 counterfeit Heptodin tablets obtained from a market survey and an additional 11 authentic Heptodin tablets for comparison. The aim of the study was to investigate whether NIR-CI can be used to detect the counterfeit tablets and to classify/source them so as to understand the possible number of origins to aid investigators and authorities to shut down counterfeiting operations. NIR-CI combined with multivariate analysis is particularly suited to compare chemical and physical properties of samples, since it is a quick and non-destructive method of analysis. Counterfeit tablets were easily distinguished from the authentic ones. Principal component analysis (PCA) and k-means clustering were performed on the data set. The results from both analyses grouped the counterfeit tablets in 13 main groups. The main groups found with both methods were quite consistent. Out of the 55 tablets only 18% contained the correct active pharmaceutical ingredient (API), i.e., the anti-viral drug lamivudine. The remaining 82% of counterfeit tablets contained talc and starch as main excipients. The API containing tablets classified into three main groups, based mainly on the amount of lamivudine present in the tablet. The group which had close to the correct amount of lamivudine sub-classified into three groups. From the analysis carried out, it is likely that the counterfeit tablets originate from as many as 15 different sources.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19110128     DOI: 10.1016/j.aca.2008.11.036

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  Survey to Identify Substandard and Falsified Tablets in Several Asian Countries with Pharmacopeial Quality Control Tests and Principal Component Analysis of Handheld Raman Spectroscopy.

Authors:  Tomoko Kakio; Hitomi Nagase; Takashi Takaoka; Naoko Yoshida; Junichi Hirakawa; Susan Macha; Takashi Hiroshima; Yukihiro Ikeda; Hirohito Tsuboi; Kazuko Kimura
Journal:  Am J Trop Med Hyg       Date:  2018-03-29       Impact factor: 2.345

2.  Classification and Visualization of Physical and Chemical Properties of Falsified Medicines with Handheld Raman Spectroscopy and X-Ray Computed Tomography.

Authors:  Tomoko Kakio; Naoko Yoshida; Susan Macha; Kazunobu Moriguchi; Takashi Hiroshima; Yukihiro Ikeda; Hirohito Tsuboi; Kazuko Kimura
Journal:  Am J Trop Med Hyg       Date:  2017-07-19       Impact factor: 2.345

3.  Quantification and spatial distribution of salicylic acid in film tablets using FT-Raman mapping with multivariate curve resolution.

Authors:  Haslet Eksi-Kocak; Sibel Ilbasmis Tamer; Sebnem Yilmaz; Merve Eryilmaz; Ismail Hakkı Boyaci; Ugur Tamer
Journal:  Asian J Pharm Sci       Date:  2017-10-20       Impact factor: 6.598

Review 4.  A Review of Pharmaceutical Robot based on Hyperspectral Technology.

Authors:  Xuesan Su; Yaonan Wang; Jianxu Mao; Yurong Chen; ATing Yin; Bingrui Zhao; Hui Zhang; Min Liu
Journal:  J Intell Robot Syst       Date:  2022-07-22       Impact factor: 3.129

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.