Robert A Gaunt1, Arthur Prochazka. 1. Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.
Abstract
BACKGROUND: Detrusor-sphincter dyssynergia is a condition in which reflexive contractions of the external urethral sphincter occur during bladder contractions, preventing the expulsion of urine. High-frequency stimulation (kHz range) has been shown to elicit a fast-acting and reversible block of action potential propagation in peripheral nerves, which may be a useful technique in the management of this condition. OBJECTIVE: The aim of these experiments was to see if a newly developed stimulus delivery system, capable of transmitting current transcutaneously to remote peripheral nerves using a passive implanted conductor, was an effective way to transmit high-frequency waveforms to the pudendal nerve to block ongoing sphincter contractions. METHODS: High-frequency waveforms were delivered through the skin to the pudendal nerve using a passive implanted conductor in 6 adult cats anesthetized with isoflurane. Five of the experiments were acute, terminal procedures, and the remaining cat was implanted with a permanent electrode system allowing evaluation for 6 months. Typical stimulation parameters were in the range of 1 to 10 kHz and 1 to 10 mA. RESULTS: Complete blocking of external urethral sphincter contractions was achieved in 5 of the 6 animals. High-frequency stimulation was also tested in the chronically implanted animal without anesthesia, and the stimulation was tolerated with minimal aversive reactions. CONCLUSIONS: The transcutaneous passive implanted conductor stimulus delivery system is an effective way to stimulate the pudendal nerve at high frequency, leading to sphincter relaxation. This system may provide a simple means to implement this stimulation paradigm in people with detrusor-sphincter dyssynergia.
BACKGROUND:Detrusor-sphincter dyssynergia is a condition in which reflexive contractions of the external urethral sphincter occur during bladder contractions, preventing the expulsion of urine. High-frequency stimulation (kHz range) has been shown to elicit a fast-acting and reversible block of action potential propagation in peripheral nerves, which may be a useful technique in the management of this condition. OBJECTIVE: The aim of these experiments was to see if a newly developed stimulus delivery system, capable of transmitting current transcutaneously to remote peripheral nerves using a passive implanted conductor, was an effective way to transmit high-frequency waveforms to the pudendal nerve to block ongoing sphincter contractions. METHODS: High-frequency waveforms were delivered through the skin to the pudendal nerve using a passive implanted conductor in 6 adult cats anesthetized with isoflurane. Five of the experiments were acute, terminal procedures, and the remaining cat was implanted with a permanent electrode system allowing evaluation for 6 months. Typical stimulation parameters were in the range of 1 to 10 kHz and 1 to 10 mA. RESULTS: Complete blocking of external urethral sphincter contractions was achieved in 5 of the 6 animals. High-frequency stimulation was also tested in the chronically implanted animal without anesthesia, and the stimulation was tolerated with minimal aversive reactions. CONCLUSIONS: The transcutaneous passive implanted conductor stimulus delivery system is an effective way to stimulate the pudendal nerve at high frequency, leading to sphincter relaxation. This system may provide a simple means to implement this stimulation paradigm in people with detrusor-sphincter dyssynergia.
Authors: Zhaocun Zhang; Timothy D Lyon; Brian T Kadow; Bing Shen; Jicheng Wang; Andy Lee; Audry Kang; James R Roppolo; William C de Groat; Changfeng Tai Journal: J Neurophysiol Date: 2016-01-06 Impact factor: 2.714
Authors: Alexander K Ommaya; Kenneth M Adams; Richard M Allman; Eileen G Collins; Rory A Cooper; C Edward Dixon; Paul S Fishman; James A Henry; Randy Kardon; Robert D Kerns; Joel Kupersmith; Albert Lo; Richard Macko; Rachel McArdle; Regina E McGlinchey; Malcolm R McNeil; Thomas P O'Toole; P Hunter Peckham; Mark H Tuszynski; Stephen G Waxman; George F Wittenberg Journal: J Rehabil Res Dev Date: 2013
Authors: D Michael Ackermann; Niloy Bhadra; Emily L Foldes; Xiao-Feng Wang; Kevin L Kilgore Journal: IEEE Trans Neural Syst Rehabil Eng Date: 2010-09-02 Impact factor: 3.802
Authors: Leah Marie Roldan; Thomas E Eggers; Kevin L Kilgore; Narendra Bhadra; Tina Vrabec; Niloy Bhadra Journal: J Neurosci Methods Date: 2019-01-11 Impact factor: 2.390
Authors: D Michael Ackermann; Emily L Foldes; Niloy Bhadra; Kevin L Kilgore Journal: IEEE Trans Neural Syst Rehabil Eng Date: 2009-10-16 Impact factor: 3.802