Doppler color flow mapping of the proximal isovelocity surface area: a new method for measuring volume flow rate across a narrowed orifice.

T Utsunomiya1, T Ogawa, H A Tang, R Doshi, D Patel, M Quan, W L Henry, J M Gardin.   

Abstract

This manuscript describes a new method, validated in in vitro models, for quantitating volume flow rate across an orifice with Doppler color flow mapping. Flow through a narrowed orifice is characterized by the convergence of radial streamlines proximal to the orifice. In this color Doppler method, one or more isovelocity surface areas (PISA), delineated by blue and red aliasing velocity interfaces, can be identified proximal to the narrowed orifice. Volume flow rate (in milliliters per second) can then be calculated as PISA (in square centimeters) multiplied by the isovelocity of the PISA (in centimeters per second). Doppler color flow mapping was performed in in vitro models of constant and pulsatile flow through an orifice in a wall. The first proximal isovelocity surface area, with an isovelocity corresponding to the aliasing velocity, that is, one half the Nyquist sampling limit, could be identified as a blue and red color interface proximal to the orifice. Over a range of circular orifice diameters from 3 mm to 16 mm and flow rates from 0.5 to 18.7 L/min, the proximal isovelocity surface area could be imaged in two planes. This PISA was best described by a hemielliptic mathematical model with two different radii measured from long-axis and short-axis views. In the constant flow model, volume flow rate calculated from the Doppler PISA correlated well with actual volume flow rate measured simultaneously with a cylinder and stopwatch (r = 0.98, p less than 0.001, standard error of the estimate [SEE] = 0.36 L/min). In the pulsatile flow model, with jet velocities ranging from 2.6 to 7.7 m/sec and flow volume ranging from 1.0 to 10.3 L/min, calculated volume flow rate also demonstrated an excellent correlation with actual volume flow rate (r = 0.99, p less than 0.001, SEE = 0.53 L/min). Findings from these in vitro models suggest that quantification of the proximal isovelocity surface area by Doppler color flow mapping appears to be a promising technique for estimating volume flow rate across a narrowed orifice. This new color Doppler flow method may have advantages over previous Doppler methods in estimating volume flow rate in various clinical situations, for example, valvular regurgitation and shunt lesions.

Entities:  

Mesh:

Year:  1991        PMID: 1910832     DOI: 10.1016/s0894-7317(14)80444-6

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  6 in total

1.  Regurgitant heart valve flow from 2-D proximal velocity field: continued search for the ideal method.

Authors:  L Eidenvall; S Barclay; D Loyd; B Wrannel; P Ask
Journal:  Med Biol Eng Comput       Date:  1995-03       Impact factor: 2.602

2.  Should clinical cardiologists incorporate the proximal isovelocity surface area (PISA) method into their ever enlarging armamentarium?

Authors:  S J Goldberg
Journal:  Heart       Date:  1997-09       Impact factor: 5.994

3.  Comparative quantification of primary mitral regurgitation by computer modeling and simulated echocardiography.

Authors:  Wenbin Mao; Andrés Caballero; Rebecca T Hahn; Wei Sun
Journal:  Am J Physiol Heart Circ Physiol       Date:  2020-01-10       Impact factor: 4.733

4.  Computational simulations of mitral regurgitation quantification using the flow convergence method: comparison of hemispheric and hemielliptic formulae.

Authors:  J Hopmeyer; E Whitney; D A Papp; M S Navathe; R A Levine; Y H Kim; A P Yoganathan
Journal:  Ann Biomed Eng       Date:  1996 Sep-Oct       Impact factor: 3.934

5.  Influence of left ventricular relaxation on the pressure half time of aortic regurgitation.

Authors:  S F de Marchi; S Windecker; B C Aeschbacher; C Seiler
Journal:  Heart       Date:  1999-11       Impact factor: 5.994

6.  Clinical application in routine practice of the proximal flow convergence method to calculate the mitral surface area in mitral valve stenosis.

Authors:  Ahmed Bennis; Abdennasser Drighil; Christophe Tribouilloy; Asmaa Drighil; Nacer Chraibi
Journal:  Int J Cardiovasc Imaging       Date:  2002-12       Impact factor: 2.357

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.