Literature DB >> 19105671

Habib laparoscopic bipolar radiofrequency device: a novel way of creating an avascular resection margin in laparoscopic partial nephrectomy.

Sero Andonian1, Adebukola Adebayo, Zeph Okeke, Benjamin R Lee.   

Abstract

INTRODUCTION: Hemostasis during the laparoscopic partial nephrectomy (LPN) is a challenge. Usually, the renal hilum is clamped to minimize blood loss. However, prolonged ischemia leads to irreversible damage. Therefore, new technology is needed to minimize blood loss while performing LPN without hilar clamping. The Habib 4x Laparoscopic device (Angio Dynamics, Queensbury, NY) is a four-pronged bipolar radiofrequency probe that is proven to reduce blood loss in laparoscopic liver resections without hilar clamping. The aim of this pilot study was to evaluate this new technology in LPN.
METHODS: Three patients, with exophytic renal lesions (1.1-4 cm), underwent LPN without hilar clamping, using the Habib Laparoscopic device to create an avascular resection margin.
RESULTS: Mean operative time was 150.3 minutes, mean estimated blood loss was 100 cc, and none of the patients required transfusions. There was no significant difference between the mean pre- and postoperative serum creatinine levels (P > 0.05). All 3 resected masses were renal-cell carcinomas. Intraoperative frozen sections demonstrated negative margins in all cases. However, in the second case, with a renal lesion of 4 cm, the permanent section analysis on margins was read as focally positive. There were no complications. On follow-up imaging of up to 12 months, there were no recurrences.
CONCLUSIONS: The Habib 4x Laparoscopic device permits the resection of exophytic renal lesions without the need for hilar clamping. However, a cautery artifact can cause difficulty in interpreting the frozen-section analysis of resection margins. Therefore, its use should be restricted to lesions of less than 2 cm.

Entities:  

Mesh:

Year:  2008        PMID: 19105671     DOI: 10.1089/lap.2008.0050

Source DB:  PubMed          Journal:  J Laparoendosc Adv Surg Tech A        ISSN: 1092-6429            Impact factor:   1.878


  4 in total

1.  Robotic-assisted laparoscopic cryo-partial nephrectomy: a novel technique using cryoablation in lieu of hilar clamping in a porcine model.

Authors:  Frank J Penna; Drew A Freilich; Beth A Drzewiecki; Alan B Retik; Hiep T Nguyen
Journal:  J Robot Surg       Date:  2010-08-21

2.  Robotic-assisted versus traditional laparoscopic partial nephrectomy: comparison of outcomes and evaluation of learning curve.

Authors:  Phillip M Pierorazio; Hiten D Patel; Tom Feng; Jithin Yohannan; Elias S Hyams; Mohamad E Allaf
Journal:  Urology       Date:  2011-07-29       Impact factor: 2.649

3.  Laparo-endoscopic single-site surgery for radical and cytoreductive nephrectomy, renal vein thrombectomy, and partial nephrectomy: a prospective pilot evaluation.

Authors:  Ithaar H Derweesh; Jonathan L Silberstein; Wassim Bazzi; Ryan Kopp; Tracy M Downs; Christopher J Kane
Journal:  Diagn Ther Endosc       Date:  2010-06-07

4.  Multicenter experience with nonischemic multiport laparoscopic and laparoendoscopic single-site partial nephrectomy utilizing bipolar radiofrequency ablation coagulator.

Authors:  Wassim M Bazzi; Mohamad E Allaf; Jared Berkowitz; Hany N Atalah; Sijo Parekattil; Ithaar H Derweesh
Journal:  Diagn Ther Endosc       Date:  2011-06-20
  4 in total